Insert revision cover from the front.
Place revision shaft.
Double-clad (2 x 12.5 mm) and tile WC element with IFGP cladding
panels (model 8055.10).
3.2.3
Preparing optional actuation versions
The corresponding empty pipe (included in the scope of delivery of the
remote actuation) is required when preparing the remote actuation
Visign for Public1 (model 8326.21).
Lead the empty pipe from the hollow wall socket into the concealed
cistern.
Distance from the remote actuation to the cistern (x)
n
min. 1.0 m
n
max. 1.7 m
A corresponding empty pipe (not included in the scope of delivery of the
electrical actuation) is required for the preparation of the electrical
actuation (model 8350.31 or model 8350.32).
Lead empty pipe from the switch or button into the concealed cis‐
tern, to connect the concealed socket and concealed cistern.
Positioning of the cistern power pack
n
X1= max. 0.75 m
n
X2= max. 2.75 m with an extension cable, 1 x article number 628 505
n
X3= max. 4.75 m with two extension cables, 2 x article number 628
505
Prepare remote actuation
X
X
Prepare electrical actuation
X1
X2
X3
Handling
Viega Eco Plus WC element
21 from 23