3 Handling
3.1
Assembly information
3.1.1
Mounting conditions
The following requirements exist for the mounting of the drain:
n
The shower tray is installed.
n
The drainage line is installed all the way to the shower tray.
n
The underside of the shower tray is accessible.
n
The drainage capacity is sufficient at an accumulation height of
120 mm.
3.1.2
Installation dimensions
90
Ø
85
Ø
Fig. 2: Dimensional drawing
3.2
Assembly
3.2.1
Mounting the drain
Proceed as follows to mount the drain:
Place the seal on the sealing surface of the drain and push into the
holding groove.
Insert seal
Handling
Domoplex drain equipment
8 from 15