Viega Domoplex 6928.21 Скачать руководство пользователя страница 11

Align the odour trap in such a way that the drain elbow can be con-
nected to the waste water pipe.

Push waste water pipe onto the drain elbow.

3.2.3

Leakage test

The leakage test is only carried out as a visual inspection.

Check drain fitting for visible leaks.

3.3

Maintenance

NOTICE! 

Risk of damage due to unsuitable cleaning agent.
The following cleaning agents can damage chrome-plated
surfaces and therefore may not be used:

– scouring agent
– abrasive sponges
– lime, plaster or cement dissolver
– solvents or other acidic cleaning agents

Normal soap or a mild cleaning agent can be used for regular care and
prevention of lime scale on the rotatable rosette and valve cone. Under
no circumstances should scouring agent or scratching objects be used.

Strong stains, even around the drain unit and the siphon, can be
removed using typical household cleaner. It should be noted that the
cleaning agent should be rinsed off after the prescribed soaking time.
There should be no residue on the components.

3.4

Cleaning the drain

NOTICE! 

Be careful not to damage the odour trap when cleaning the
drain system.

Handling

Domoplex drain equipment

11 from  15

Содержание Domoplex 6928.21

Страница 1: ...Model Year built 6929 from 06 2015 en_INT Domoplex drain equipment Instructions for Use...

Страница 2: ...Domoplex drain equipment 2 from 15...

Страница 3: ...use 6 2 2 Product description 7 2 2 1 Overview 7 2 2 2 Technical data 7 3 Handling 9 3 1 Assembly information 9 3 1 1 Mounting conditions 9 3 1 2 Installation dimensions 9 3 2 Assembly 9 3 2 1 Mounti...

Страница 4: ...This restriction does not extend to possible operating instructions The installation of Viega products must take place in accordance with the general approved rules of engineering and the Viega instr...

Страница 5: ...rds in Europe e g EN and or in Germany e g DIN DVGW Some passages in the text may refer to technical codes in Europe Germany These should serve as recommendations in the absence of corresponding natio...

Страница 6: ...s with a pH value higher than 4 typical household water with a maximum temperature of 95 C The Domoplex shower drain is a drain with odour trap for shower trays with 65 mm drain holes Detailed informa...

Страница 7: ...7 sliding ring 8 union nut 9 drain elbow 2 2 2 Technical data Drainage capacity at an accumulation height of 120 mm 0 73 l s Diameter drain hole 65 mm DN nominal diameter drain support 40 50 mm Heigh...

Страница 8: ...ower tray n The underside of the shower tray is accessible n The drainage capacity is sufficient at an accumulation height of 120 mm 3 1 2 Installation dimensions 90 85 Fig 2 Dimensional drawing 3 2 A...

Страница 9: ...r part of the seal through the drain hole Place fixing flange and insert the screws by hand NOTICE Only use a screwdriver not a cordless screwdriver Tighten screws evenly Insert immersion pipe into th...

Страница 10: ...ain to the waste water system Requirement n The drain unit is installed onto the shower tray If the waste water pipe only has a diameter of 40 mm cut off drain elbow Push the union nut sliding ring an...

Страница 11: ...er or cement dissolver solvents or other acidic cleaning agents Normal soap or a mild cleaning agent can be used for regular care and prevention of lime scale on the rotatable rosette and valve cone U...

Страница 12: ...ve the immersion pipe upwards For free access to the drain pipe Grip the closing plug on the lug with pliers and pull off Clean the drain carefully to avoid damaging the fitting Handling Domoplex drai...

Страница 13: ...closing plug flush with the surface Make sure to position the closing plug properly The lug must be positioned vertically Insert immersion pipe Mount cover plate Handling Domoplex drain equipment 13 f...

Страница 14: ...osal Separate the product and packaging materials e g paper metal plastic or non ferrous metals and dispose of in accordance with valid national legal requirements Handling Domoplex drain equipment 14...

Отзывы: