![Viega 8625.1 Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/viega/8625-1/8625-1_instructions-for-use-manual_1016601023.webp)
NOTICE!
Damage due to moisture
Risk of damage to the drive unit if moisture penetrates.
n
Do not remove the protective cover of the DIP
switches.
Setting the flush volumes (A)
Program no.
Large flush
volume (in litres)
Small flush
volume
(in litres)
Position of the
switches 1—4
1
2
3
4
Program 0
(factory set‐
ting)
6
3
0
0
0
0
Program 1
3.5
2
0
0
0
1
Program 2
4.5
2
0
0
1
0
Program 3
6
2
0
0
1
1
Program 4
7.5
2
0
1
0
0
Program 5
3.5
3
0
1
0
1
Program 6
4.5
3
0
1
1
0
Program 7
7.5
3
0
1
1
1
Program 8
4.5
4
1
0
0
0
Program 9
6
4
1
0
0
1
Program 10
7.5
4
1
0
1
0
Viega Enabling the function and setting the intervals (B)
Interval (in hours)
Position of switches 5—7
5
6
7
Switched off
0
0
0
1
0
0
1
12
0
1
0
24
0
1
1
72
1
0
0
168
1
0
1
Handling
WC flush plate for Prevista Visign for More 205 sensitive
23