3.2.3
Connecting external sensors
NOTICE!
Damage to property due to excess voltage
If you apply voltage to the connection cable for the
external button, you will damage the control.
n
Do not apply any external voltage!
Requirements:
n
Button with locking function or potential-free contact (closure time at
least 350 ms) available
n
Connection cable available
▶
Connect the contact to actuate the small flush volume between the
green (1) and yellow cable (3).
▶
Connect the contact to actuate the large flush volume between the
green (1) and white cable (2).
▶
Strip the end of the brown cable (e.g., with a lustre terminal).
Fig. 3: WC flush plate, terminal assign‐
ment for external sensors
Fig. 4: WC flush plate, terminal assign‐
ment for external sensors
Handling
WC flush plate for Prevista Visign for More 205 sensitive
21