3.2.3
Connecting external sensors
NOTICE!
Damage to property due to excess voltage
If you apply voltage to the connection cable for the external
button, you will damage the control.
– Do not apply any external voltage!
Requirements:
n
Button with locking function or potential-free contact (closure time at
least 350 ms) available
n
Connection cable available
Connect the contact to actuate the small flush volume between the
green (1) and yellow cable (3).
Connect the contact to actuate the large flush volume between the
green (1) and white cable (2).
Strip the end of the brown cable (e.g., with a lustre terminal).
Fig. 3: WC flush plate, terminal assignment
for external sensors
Fig. 4: WC flush plate, terminal assignment
for external sensors