Insert the drain elbow into the lip seal of the odour trap.
Identify possible sizes on the drain elbow and adjusting pipe that
may have to be shortened.
Shorten drain elbow and adjusting pipe, if necessary.
Deburr the interface and grease the lip seal.
Insert the drain elbow through the cover plate in the lip seal of the
odour trap.
INFO! The adjustment range of the odour trap is 20 mm up and
down.
Attach the cover plate to the concealed connection box. The lateral
bars serve as anti-twist protection.
x
x
+20 mm
Handling
Viega Eco Plus washbasin element,
individually height-adjustable