Lead empty pipe from the switch or button into the concealed cis‐
tern, to connect the concealed socket and concealed cistern.
Positioning of the cistern power pack
n
X1= max. 0.75 m
n
X2= max. 2.75 m with an extension cable, 1 x article number 628 505
n
X3= max. 4.75 m with two extension cables, 2 x article number 628
505
3.2.4
Setting the flush volume
Immediate re-flushing of the flush volume is possible at the
factory settings.
The WC element is factory-set at a small flush of approx. 3 l. The small
flush volume can be set at three levels: approx. 3 l / 3.5 l / 4 l.
Remove the drain valve from the concealed cistern.
Push the slide control on the side of the overflow pipe to the desired
small flush volume:
n
Top position: approx. 3 l
n
Middle position: approx. 3.5 l
n
Bottom position: approx. 4 l
The positions can be identified by the notches.
The WC element is factory-set at a large flush volume of approx. 6 l. The
large flush volume can be set continuously from approx. 6 l up to
approx. 9 l.
Remove the drain valve from the concealed cistern.
Prepare electrical actuation
X1
X2
X3
Small flush volume
Large flush volume
Handling
Viega WC element
19 from 20
Содержание 8139
Страница 2: ...Viega WC element 2 from 20 ...