background image

2 Product information

2.1

Standards and regulations

The following standards and regulations apply to Germany / Europe and

are provided as a support feature.

Scope / Notice

Regulations applicable in Ger‐

many

Planning, execution, operation

and maintenance of potable water

installations

DIN EN 806, part 1

Planning, execution, operation

and maintenance of potable water

installations

DIN EN 806, part 2

Planning, execution, operation

and maintenance of potable water

installations

DIN EN 806, part 3

Planning, execution, operation

and maintenance of potable water

installations

DIN EN 806, part 4

Planning, execution, operation

and maintenance of potable water

installations

DIN EN 806, part 5

Planning, execution, operation

and maintenance of potable water

installations

DIN EN 1717

Planning, execution, operation

and maintenance of potable water

installations

DIN 1988

Planning, execution, operation

and maintenance of potable water

installations

VDI/DVGW 6023

Planning, execution, operation

and maintenance of potable water

installations

Trinkwasserverordnung (TrinkwV)

Scope / Notice

Regulations applicable in Ger‐

many

Suitability for drinking water

Trinkwasserverordnung (TrinkwV)

Suitability for heating water for

pump hot water heating systems

VDI 2035 Page 1 and page 2

Regulations from section: Fields of application

Regulations from section: Media

Product information

Easytop ball valve

6 from  15

Содержание 2270.2

Страница 1: ...Model Year built 2275 2 from 07 2017 en_INT Easytop ball valve Instructions for Use...

Страница 2: ...Easytop ball valve 2 from 15...

Страница 3: ...2 Media 9 2 3 Product description 9 2 3 1 Overview 9 2 3 2 Threaded connection 10 2 3 3 Markings on components 10 2 3 4 Compatible components 10 2 3 5 Technical data 10 2 4 Information for use 11 2 4...

Страница 4: ...operating instructions The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use 1 2 Labelling of notes Warning and adv...

Страница 5: ...or in Germany e g DIN DVGW Some passages in the text may refer to technical codes in Europe Germany These should serve as recommendations in the absence of corresponding national regulations The rele...

Страница 6: ...ng execution operation and maintenance of potable water installations DIN EN 806 part 5 Planning execution operation and maintenance of potable water installations DIN EN 1717 Planning execution opera...

Страница 7: ...group I DIN EN 13828 Scope Notice Regulations applicable in Ger many Threaded pair DIN EN 10226 1 Permitted sealants DIN 30660 Permitted sealants DIN EN 751 2 Scope Notice Regulations applicable in Ge...

Страница 8: ...e of potable water installations DIN EN 806 5 2 2 Intended use Coordinate the use of the model for areas of use and media other than those described with the Viega Service Center A ball valve is a fit...

Страница 9: ...s see Regulations from section Media on page 6 n Heating water for pump hot water heating systems see Regula tions from section Media on page 6 n Compressed air in compliance with the specification of...

Страница 10: ...mitted threaded pair comprises a conical external thread and a cylindrical internal thread e g R and Rp Only use commercially available and chloride free DVGW approved sealant in accordance with the a...

Страница 11: ...sion protection is required observe the pertinent guide lines see Regulations from section Corrosion on page 8 Easytop fittings made of gunmetal silicon bronze are suit able for all types of potable w...

Страница 12: ...Fig 1 Model 2275 93 Easytop L shaped actuating lever Fig 2 Model 2275 92 Easytop T shaped actuating lever Fig 3 Model 2275 94 Easytop thermometer Product information Easytop ball valve 12 from 15...

Страница 13: ...sulating shells are available for all sizes of ball valves The two piece shells are self supporting and are mounted without tools and holding grips They connect seamlessly to the front surfaces of the...

Страница 14: ...ing when mounting n Use suitable tools n Installation is not dependent on the direction of flow Choose the place of installation so that the fitting is easily accessible simple to operate and the insu...

Страница 15: ...ment the result 3 3 Maintenance NOTICE Inform your customer or the operator of the potable water installation that the system has to be maintained on a reg ular basis Observe the applicable regulation...

Отзывы: