130A/160A/180A/200A/250A INVERTER MMA DC WELDING MACHINE 

ENG

Содержание WD060111013U

Страница 1: ...INVERTER MMA DC WELDING MACHINE WD060111013U WD060111016 WD060111018 WD060111020 WD060111025 130A 160A 180A 200A 250A...

Страница 2: ...ng a VIDO product We are confident that you will appreciate the quality of the product and you will be entirely satisfied with your purchase Please read carefully the user safety and operating instruc...

Страница 3: ...3 WD060111013U WD060111016 WD060111018 WD060111020 WD060111025 1 7 2 4 5 3 6...

Страница 4: ...4 10 200 100 WD060111013U WD060111016 WD060111018 WD060111020 WD060111025 x 9 1 8 10 2 3 6 5 4 9 8 7 11 10...

Страница 5: ...pc 2 Ground clamp with cable 1pc 3 Protective mask 1pc 4 Hammer brush 1pc 5 Belt 1pc We recommend that you purchase your accessories from the same store that sold you the welding machine Use good qual...

Страница 6: ...frozen pipes Turn off all equipment when welder not in use Fumes can be dangerous Fumes emitted from the welding process displace clean air and can result in injury or death Do not breathe in fumes em...

Страница 7: ...ts that are oil free with no pockets or cuffs that will collect sparks Do not have on your person any items that are combustible such as lighters or matches Keep work lead connectedas close to the wel...

Страница 8: ...of the cable should be bigger to reduce the lower of the cable voltage GROUNDING INSTRUCTIONS This welding machine should be grounded while in use to protect the operator from electric shock The weldi...

Страница 9: ...risk Wear eye protection Wear ear protection Direct correction DC Single phase static frequency converter transformer rectifier Waste electrical products should not be disposed of with household waste...

Страница 10: ...d voltage 85V DC 85V DC 85V DC Output range 10 130ADC 10 160A DC 10 180ADC Duty cycle 60 130A 60 160A 60 180 A m m 0 4 6 1 m m 0 4 6 1 m m 0 4 6 1 r e t e m a i d e d o r t c e l E Ingress protection...

Страница 11: ...output cable a The electrode holder cable is connected to the output terminal of the welding machine Insert the connector with the key lining up with the keyway and rotate approximately 1 3 turn cloc...

Страница 12: ...the electrode in relation to the workpiece should be between 600 and 800 degrees This will allow for good penetration with minimal spatter 5 Striking the arc Warning Exposure to a welding arc is extr...

Страница 13: ...ld speed is too fast B Weld speed is too slow C Arc is too long D Ideal weld Note A solid weld bead requires that the electrode be moved slowly and steadily along the weld seam Warning Electric shock...

Страница 14: ...Remove the plug from the socket before carrying out any adjustment servicing or maintenance 1 Never use water or chemical cleaners to clean your welding machine Only wipe clean with a dry cloth 2 Und...

Страница 15: ...upply is lower or higher than required range Contact your local power supply enterprise Electrode holder or ground cable getting hot Output connections getting hot Weld cable connections loose Check t...

Страница 16: ...l PCB 1 4 Fan 1 18 Current carrying plate 1 5 Rear cover 1 19 Current carrying plate 1 6 Power switch 1 20 Base plate 1 7 Support bar of IGBT radiator 1 21 Quick connector 2 8 Radiator 2 22 Currentsel...

Страница 17: ...urrent carrying plate 1 5 Rear cover 1 20 Base plate 1 6 Fan 1 21 Quick connector 2 7 Radiator 1 22 Front cover 1 8 Bridge rectifiers 1 23 Current carrying plate 1 9 Radiator 2 24 Currentselectorknob...

Страница 18: ...5 Shade of LED 2 21 Radiator 1 6 Digital display instrument 1 22 IGBT single tube 4 7 Front cover 1 23 Radiator 2 8 Base plate 1 24 Support bar of IGBT radiator 1 9 Quick connector 2 25 Rear cover 1 1...

Страница 19: ...ar of IGBT radiator 1 22 Nut 1 5 Radiator 2 23 Shade of LED 2 6 Power switch 1 24 Current selector knob 1 7 IGBT single tube 4 25 Current carrying plate 1 8 Cable gland 1 26 Current carrying plate 1 9...

Страница 20: ...Shade of LED 2 21 Radiator 1 6 Digital display instrument 1 22 IGBT single tube 4 7 Front cover 1 23 Radiator 2 8 Base plate 1 24 Support bar of IGBT radiator 1 9 Quick connector 2 25 Rear cover 1 10...

Страница 21: ...WD060111013U WD060111016 WD060111018 WD060111020 WD060111025 21...

Страница 22: ...WD060111013U WD060111016 WD060111018 WD060111020 WD060111025 22...

Страница 23: ...WD060111013U WD060111016 WD060111018 WD060111020 WD060111025 23...

Страница 24: ...MADE IN CHINA Copyright WIDO Machinery Co Ltd All rights reserved www widopt com...