Operation
62
Vidikron Vision Model 65/Model 75 Installation/Operation Manual
Changing either or both of these numbers changes the hue of the color and relocates the
“triangle” for possible colors. For example, changing the x/y coordinates for red moves the
color closer to either orange or violet, which in turn affects all displayed colors having a
red component.
To adjust the gamut:
1.
Select Gamut from the Advanced Options menu and press
ENTER
.
2.
To do an automatic gamut adjustment, highlight “Enter” and press
ENTER
. If further
calibration is necessary, continue with the next step.
3.
Highlight “Settings” and press
or
to select “Manual.”
4.
Highlight “White” and press
ENTER
. The Vision 65/75 displays a white field on the screen.
5.
Using the color analyzer, measure the x and y coordinates for about 15 seconds. Make a
note of the results.
6.
Press
EXIT
or
ENTER
.
7.
Highlight “White” and press
.
8
.
Press
ENTER
to select the first digit of the x coordinate value for White (obtained in
Step 5).
9.
Press
or
repeatedly to set the digit.
10. Press
to select the next digit; use the
and
buttons to change it.
11. Repeat Step 10 for the third digit.
12. Press
ENTER
.
13. Press
to highlight the “y” coordinate value for White. Then, press
ENTER
to select the
first digit.
14. Repeat Steps 9 through 12 to set the “y” coordinate value for White.
15. Press
to highlight the “Y” coordinate value. Then press
ENTER
to select the first digit.
16. Repeat Steps 9 through 12 to set the “Y” coordinate value for White.
17. Press
EXIT
.
1
8
. Repeat Steps 4 through 17 for Red, Green, Blue and D. White (Desired White).
19. Highlight “Save” and press
ENTER
.
To undo the effects of a previous calibration, highlight “Settings” and press
or
to select
“Default.”
Reset to Defaults:
To restore the ISF default image settings for the current input source
ONLY, select Reset to Defaults and press the
button to highlight “Yes.” Then, press
ENTER
.
To perform these adjustments, you will need a color analyzer (Sencore
ColorPro 5000 software and ColorPro III sensor, or equivalent).
Note
Gamut
Settings
Manual
White
x:312
y:329
Y:045
Red
x:640
y:330
Y:015
Green
x:300
y:600
Y:022
Blue
x:150
y:060
Y:018
D. White
x:312
y:329
Y:045
Enter
Save
Color Temp.
6500
White
x:000
y:000
Y: 000
Содержание Vision 65
Страница 2: ......
Страница 14: ...Table of Contents xiv Vidikron Vision Model 65 Model 75 Installation Operation Manual Notes...
Страница 82: ...Maintenance and Troubleshooting 66 Vidikron Vision Model 65 Model 75 Installation Operation Manual Notes...
Страница 86: ...Serial Communications 70 Vidikron Vision Model 65 Model 75 Installation Operation Manual Notes...
Страница 94: ...Specifications 78 Vidikron Vision Model 65 Model 75 Installation Operation Manual Notes...
Страница 95: ......
Страница 96: ...1 888 4 VIDIKRON Fax 503 748 8161 www vidikron com SERIAL NUMBER 020 0715 02 Rev A March 2008...