Videx VX8800 Скачать руководство пользователя страница 3

VX8800 1.0 05/10/07 23/03/10

ENTER THE 

ENGINEER’S CODE

RE-ENTER THE

ENGINEER’S CODE

ENTER ACCESS 

CODE

ENTER ACCESS 

TIME

MORE

DOORS ?

PRESS ENTER 

TWICE TO EXIT 

PROGRAMMING

ALTERNATIVELY  ENTER 

A  NEW  ENGINEER’S 

CODE (4 TO 8 DIGITS)
RELAY  CODE  (4-8  DIG-

ITS) 

OPERATE 

THE 

DOOR OR GATE.**
TWO  DIGITS  (01-99  Sec 

OR  00  FOR  REMAIN 

OPEN)

Notes:

*   If the red light does not illuminate, the engineer’s code is incorrect. Follow 

instructions to return system to preset engineer’s factory code.

**  On the first loop of the flow chart its relay 1 while second loop is relay 2.

YES

Press Enter

(Red light will illuminate*)

Press Enter

Press Enter

Press Enter

Repeat steps for relay 2

NO

DIGITARE IL CODI-

CE INSTALLATORE

DIGITARE NUOVA-

MENTE IL CODICE

DIGITARE IL CODI-

CE DI ACCESSO

DIGITARE IL TEMPO 

DI ATTIVAZIONE 

RELè

ALTRI 

RELè?

PREMERE 2 VOLTE 

ENTER PER

USCIRE

ALTERNATIVELY  ENTER 

A  NEW  ENGINEER’S 

CODE (4 TO 8 DIGITS)
RELAY  CODE  (4-8  DI-

GITS)  OPERATE  THE 

DOOR OR GATE.**
TWO  DIGITS  (01-99  Sec 

OR  00  FOR  REMAIN 

OPEN)

Notes:

*   Se il LED rosso non si accende, il codice installatore non è corretto. Seguire 

le istruzioni per ripristinare il codice installatore di fabbrica.

**  Al primo passaggio del flow chart si sta operando sul relé 1 mentre al secon-

do passaggio sul relé 2.

SI

Premere Enter

(il LED rosso si accende*)

Premere Enter

Premere Enter

Premere Enter

Ripetere  le  stesse  opera-

zioni per il relé 2

NO

engineer’s code
relay 1 code
relay 2 code

relay 1 time
relay 2 time

codice installatore
codice relé 1
codice relé 2

tempo relé 1
tempo relé 2

SE

0

ART.522

230V

FUSE

12V

Door Open Button

Lamp Button

ART.321

LAMP

24V

ac/dc 5A

 max

POWER

VX8800

+

-

C1

NC1

NO1

NO2

C2

NC2

SW1

SW2

12

¸

24

Vac/dc

VX8800.dwg

guida alla riProgrammazione

re-proGramminG Guide

Содержание VX8800

Страница 1: ...seconds according to the number of mistakes self protection Keypad includes panel illumination and 2 LED s to show the following Correct relay code green LED on for 2 seconds Red LED to indicate when in the programming menu Contacts of the relays are available N O and N C with 5A max 24Vac dc Power requirements 12 24V AC DC 2VA Working temperature 10 50 C To use the system type in the programmed c...

Страница 2: ...ocare degli spike per evitare tale inconveniente si consiglia di collegare tra i terminali della serratura un va ristore Fig 1A o un diodo Fig 1B a seconda che la serratura sia in alternata o in continua refer also to flow chart Enter ENGINEER S CODE first time type six times 1 111111 factory pre set and press ENTER The red LED will illuminate Confirm ENGINEER S CODE typing again the same or type ...

Страница 3: ...are il tempo di attivazione relè altri relè premere 2 volte enter per uscire ALTERNATIVELY ENTER A NEW ENGINEER S CODE 4 TO 8 DIGITS RELAY CODE 4 8 DI GITS OPERATE THE DOOR OR GATE TWO DIGITS 01 99 Sec OR 00 FOR REMAIN OPEN Notes Se il LED rosso non si accende il codice installatore non è corretto Seguire le istruzioni per ripristinare il codice installatore di fabbrica Al primo passaggio del flow...

Страница 4: ...2 P1 C 1 C CP C NC Art 8835 2 A Art 8834 Art 8845 SE 12V 230 Vac 0 Art 522 Art 322 1 c 9 8 3 S 3 15 16 17 C Local Bell 1 2 Local Bell NO1 12 24Vac dc C1 NC1 C2 NO2 NC2 SW2 SW1 Art 8800 14 13 Art 3131 3141 Art 3131 3141 VX8800 8837M dwg 2 1 3 2 1 5 SE Art 8837 2 2 3 1 4 X P P C 1 2 12V Art 924 4 6 2 BLUE RED WHITE 3 1 5 9 8 Art 924 4 6 2 BLUE RED WHITE 3 1 5 9 8 6 n 6 Art 8845 3 C SW1 VX8800 NC1 NO...

Отзывы: