fare riferimento al flow chart

• Digitare il “MASTER CODE”: 6 volte “1” (111111 impostazione di fabbrica) e 

premere ENTER (il LED rosso si accende).

• Confermare  il  “MASTER  CODE”  (digitandolo  nuovamente)  o  digitarne  uno 

nuovo (da 4 ad 8 cifre) quindi premere ENTER (segnale acustico). Premendo 

due volte ENTER senza modificare il “MASTER CODE” si esce dalla program-

mazione.

• Digitare il codice di attivazione (da 4 ad 8 cifre) del “RELè 1” quindi premere 

ENTER (segnale acustico).

• Digitare il tempo di funzionamento del “RELé 1” (2 cifre da 01 a 99 Es.05=5 se-

condi 00=Commutazione di stato) quindi premere ENTER (segnale acustico).

• Digitare il codice di attivazione (da 4 ad 8 cifre) del “RELè 2” quindi premere 

ENTER (segnale acustico).

• Digitare il tempo di funzionamento del “RELé 2” quindi premere ENTER (se-

gnale acustico).

• Il sistema è pronto all’uso (il LED rosso si spegne).

istruzioni  Per  riPortare  il  sistema al  codice  master 

imPostato di faBBrica

• Togliere l’alimentazione alla tastiera.

• Tenendo premuto il tasto “ENTER”, dare nuovamente alimentazione alla ta-

stiera.

• Rilasciare il tasto “ENTER”.

• Il MASTER CODE è nuovamente quello di fabbrica “111111” (6 volte “1”).

• Procedere con la nuova programmazione.

note

• Per  disattivare  uno  dei  relè  mentre  è  in  funzione,  digitare  il  relativo  codice 

quindi premere il tasto “CLEAR”.

• Per far funzionare i relè contemporaneamente, impostare lo stesso codice di 

attivazione per ciascun relè.

• Se viene digitato un codice errato, l’unità si blocca per 5 secondi: il tempo di 

blocco aumenta in base al numero di errati inserimenti. L’unità funzionerà solo 

digitando un codice corretto.

Per eseguire una corretta installazione è necessario impiegare esclusivamente 

parti VIDEX, seguire con scrupolo quanto indicato negli schemi di collegamento 

e tenere presenti le norme generali d’installazione:

• Realizzare gli impianti secondo le vigenti normative nazionali ed in ogni caso si 

consiglia di prevedere, per i conduttori dell’impianto, una canalizzazione distin-

ta da quella della linea elettrica (vedi paragrafo seguente per il collegamento 

alla linea elettrica e l’installazione dell’alimentatore);

• Impiegare conduttori con sezioni tali da avere:

 -resistenza complessiva inferiore a 10  per quelli della linea fonica e di co-

mando;

 -resistenza complessiva inferiore a 3  per quelli della serratura e di alimen-

tazione;

• Verificare le connessioni prima di dare alimentazione all’impianto;

• Alimentare l’impianto ed eseguire il collaudo verificandone tutte le funzioni

azionamento serratura - Protezione dai disturBi

L’azionamento  della  serratura  elettrica  può  provocare  degli  spike,  per  evitare 

tale inconveniente si consiglia di collegare tra i terminali della serratura un va-

ristore (Fig.1A) o un diodo (Fig.1B) a seconda che la serratura sia in alternata 

o in continua.

refer also to flow chart

• Enter “ENGINEER’S CODE”: first time type six times “1” (111111 factory pre-

set) and press ENTER (The red LED will illuminate).

• Confirm “ENGINEER’S CODE” (typing again the same) or type the new code 

(4 to 8 digits) then press ENTER (Melody). Pressing twice the ENTER button 

without changing the “ENGINEER’S CODE”, will exit from the programming.

• Enter the code (4 to 8 digits) to enable “RELAY 1” (ACCESS 1) or re-enter the 

existing code then press ENTER (Melody).

• Enter the  “RELAY 1” operation time (2 digits 01 to 99 I.E. 05=5 seconds, 00= 

remain open time) or re-enter the existing time then press ENTER (Melody).

• Enter the code (4 to 8 digits) to enable “RELAY 2” (ACCESS 2) or re-enter the 

existing code then press ENTER (Melody).

• Enter the  “RELAY 2” operation time (2 digits 01 to 99 I.E. 05=5 seconds, 00= 

remain open time) or re-enter the existing time then press ENTER (Melody).

• The system is ready to use (the red LED will be off).

instruction  to  return  sYstem  to  preset  enGineer’s 

factorY code

• Turn off power to code lock.

• Keep “ENTER” button pressed while turning back on the power to the code 

lock.

• Release “ENTER” button.

• The master code is now set at factory engineer’s code “111111” (six times “1”).

• Proceed with programming for a new system.

notes

• To switch off any relay while operating, type in the relevant code then press 

the “CLEAR” button.

• To operate relays together, set the same code for each relay.

• If a wrong code is entered, the system will lock out for 5 seconds which will in-

crease each time a wrong code is entered. The system will operate only when 

the correct code is entered.

In order to achieve the best results from the schematics described it is necessary 

to install only original VIDEX equipment, strictly keeping to the items indicated 

on each schematic and follow these General Directions for Installation:

• The system must be installed according to national rules in force, in any case 

the running of cables of any intercom unit must be carried out separately from 

the mains;

• All multipair cables should be compliant to CW1308 specification (0.5mm twist-

ed pair telephone cable.

 

-

Cables for speech line and service should have a max resistance of 10

 

-

Lock release wires should be doubled up (Lock release wires and power sup-

ply wires should have a max resistance of 3 );

• The cable sizes above can be used for distances up to 50m. On distances 

above 50m the cable sizes should be increased to keep the overall resistance 

of the cable below the RESISTANCES indicated above;

• Double check the connections before power up;

• Power up the system then check all functions.

locK release BacK emf protection

A  MOV  (VARISTOR)  must  be  fitted  across  the  terminals  on AC  lock  release 

(Fig.1A) and a diode must be fitted across the terminals on a DC lock release 

(Fig.1B) to suppress back EMF voltages. Connect this components to the lock 

releases as shown in figures.

Programmazione

proGramminG 

norme generali d’installazione

General directions for installation

Содержание VX8800

Страница 1: ...seconds according to the number of mistakes self protection Keypad includes panel illumination and 2 LED s to show the following Correct relay code green LED on for 2 seconds Red LED to indicate when in the programming menu Contacts of the relays are available N O and N C with 5A max 24Vac dc Power requirements 12 24V AC DC 2VA Working temperature 10 50 C To use the system type in the programmed c...

Страница 2: ...ocare degli spike per evitare tale inconveniente si consiglia di collegare tra i terminali della serratura un va ristore Fig 1A o un diodo Fig 1B a seconda che la serratura sia in alternata o in continua refer also to flow chart Enter ENGINEER S CODE first time type six times 1 111111 factory pre set and press ENTER The red LED will illuminate Confirm ENGINEER S CODE typing again the same or type ...

Страница 3: ...are il tempo di attivazione relè altri relè premere 2 volte enter per uscire ALTERNATIVELY ENTER A NEW ENGINEER S CODE 4 TO 8 DIGITS RELAY CODE 4 8 DI GITS OPERATE THE DOOR OR GATE TWO DIGITS 01 99 Sec OR 00 FOR REMAIN OPEN Notes Se il LED rosso non si accende il codice installatore non è corretto Seguire le istruzioni per ripristinare il codice installatore di fabbrica Al primo passaggio del flow...

Страница 4: ...2 P1 C 1 C CP C NC Art 8835 2 A Art 8834 Art 8845 SE 12V 230 Vac 0 Art 522 Art 322 1 c 9 8 3 S 3 15 16 17 C Local Bell 1 2 Local Bell NO1 12 24Vac dc C1 NC1 C2 NO2 NC2 SW2 SW1 Art 8800 14 13 Art 3131 3141 Art 3131 3141 VX8800 8837M dwg 2 1 3 2 1 5 SE Art 8837 2 2 3 1 4 X P P C 1 2 12V Art 924 4 6 2 BLUE RED WHITE 3 1 5 9 8 Art 924 4 6 2 BLUE RED WHITE 3 1 5 9 8 6 n 6 Art 8845 3 C SW1 VX8800 NC1 NO...

Отзывы: