VX800N CODELOCK
The VX800N includes two relays (5A contacts), two push to exit inputs (Switched negative)
and can have up to two 4 to 8 digit access codes programmed (One per relay). The relay
times can be programmed from 01 second up to 99 seconds or by setting the relay time to
00, latch the relay(To latch, enter the code followed by enter and to unlatch enter the code
followed by clear).
INITIAL PROGRAMMING
All programming is carried out using the codelock keypad. The programming menu is
protected by an engineer’s code. The factory default engineers code is 111111 (6x1). This
code can be changed to any four to six digit code during the program but must be different
to the codes used to gain entry. Follow the flow chart to setup the system:-
Enter the master code.
111111
Then press enter
The red LED will illuminate to acknowledge programming mode. If the red
LED does not illuminate check the master code is correct. If the master
code may have been changed from the factory default and you do not
know what it is then follow the factory default procedure on the following
page.
Enter a new engineers
code or enter the same
engineers code again
followed by enter
This code can be from 4 – 8 digits and will not activate a relay. It can only
be used to enter programming mode.
Note this new code in the box provided on the next page. It will be needed
to re-program the codes in the future.
Enter the access code
for relay 1 and then
press enter
This code will be used to open the door/gate (Relay 1). The code can be
from 4 – 8 digits long and must be different from the engineer’s code.
Enter a two digit relay 1
time from 00 – 99 and
then press enter
This is the time the relay 1 will energise for. 00 will latch the relay when
the code is entered and require the code followed by clear to unlatch.
Enter the access code
for relay 2 and then
press enter
This code will be used to open the door/gate (Relay 2). The code can be
from 4 – 8 digits long and must be different from the engineer’s code.
Enter a two digit relay 2
time from 00 – 99 and
then press enter
This is the time the relay 2 will energise for. 00 will latch the relay when
the code is entered and require the code followed by clear to unlatch.
More
codes?
YES
NO
Press enter twice
The red LED will go off to confirm the exit from programming mode.
Содержание VRDK1/CL
Страница 1: ...TECHNICAL MANUAL EDITION 1 0 VANDAL RESISTANT ONE BUTTON CODED ACCESS DOOR ENTRY KIT VRDK1 CL 25H CL...
Страница 2: ...PAGE 2 of 12 VRDK1 CL TECHNICAL MANUAL VER1 0...
Страница 7: ...PAGE 7 of 12 VRDK1 CL TECHNICAL MANUAL VER1 0 ACCESSORIES CONNECTION GUIDE 3021 3021...
Страница 8: ...PAGE 8 of 12 VRDK1 CL TECHNICAL MANUAL VER1 0 WIRING DIAGRAM...