PAGE 3 of 12 

             VRDK1/CL TECHNICAL MANUAL 

 

VER1.0 

MANUAL INTRODUCTION 

 
The information in this manual is intended as an installation and commissioning guide for 
the vandal resistant one button audio intercom kit. This manual should be read carefully 
before the installation commences. Any damage caused to the equipment due to faulty 
installations where the information in this manual has not been followed is not the 
responsibility of Videx Security Ltd. 
 
VIDEX run free training courses for engineers who are not familiar with the Videx product 
range. Technical help is also available on 0191 224 3174 during office hours or via e-mail 
[email protected]
 

SYSTEM INTRODUCTION 

 
This kit will enable a caller at an entrance point to signal an occupant in the dwelling by 
pressing a call button which will buzz an audio telephone inside. A two way conversation 
can take place once the telephone is answered and then if required, the occupant can 
release an electric lock release by pressing a button on the telephone. Additionally users 
can gain access using an access code. The kit does not include the electric lock release. A 
12V AC release should be used with this kit.  
 

SYSTEM COMPONENTS 

 
This kit comprises of a flush vandal resistant door panel with coded access, audio 
telephone and PSU. The door panel can be converted to surface by ordering the VR/S2 
surface back box. Up to a maximum of three telephones can be used on the system to call 
in parallel. 
 

DOOR PANEL

 

 
The vandal resistant door panel will consist of an amplifier module, codelock module, 
button, vandal resistant plate and back box. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
Amplifier module (Art.437 or Art.537) 

 

Connection Function 

Receive speech from apartment 

Transmit speech to apartment 

+8Vdc to +12Vdc input 

4 0V 

(Ground) 

 

 

Codelock module connections (VX800N) 

 

12V power input from PSU 

Ground 0V from PSU 

Common connection on relay 1 

Normally open connection on relay 1 

Normally closed connection on relay 1 

Common connection on relay 2 

Normally open connection on relay 2 

Normally closed connection on relay 2 

Push to exit input triggering relay 2 

10 

Push to exit input triggering relay 1 

Содержание VRDK1/CL

Страница 1: ...TECHNICAL MANUAL EDITION 1 0 VANDAL RESISTANT ONE BUTTON CODED ACCESS DOOR ENTRY KIT VRDK1 CL 25H CL...

Страница 2: ...PAGE 2 of 12 VRDK1 CL TECHNICAL MANUAL VER1 0...

Страница 3: ...ock release by pressing a button on the telephone Additionally users can gain access using an access code The kit does not include the electric lock release A 12V AC release should be used with this k...

Страница 4: ...his power supply TELEPHONE Art 3021 BLOCK DIAGRAM CONNECTIONS Terminal Function 12 12Vdc output 200mA Max 8 8Vdc output 300mA Max 0V Ground 13Vac 1A Max 230 Mains in Live connection 0 Mains in Neutral...

Страница 5: ...gulations Install an appropriate fused spur or isolation switch to isolate the mains Isolate the mains before carrying out any maintenance work on the system All intercom and access control cables mus...

Страница 6: ...uld be located as close to the door panel as possible for best performance Maximum acceptable resistance for above cables 3 TESTING THE INSTALLATION Check all the connections have been made correctly...

Страница 7: ...PAGE 7 of 12 VRDK1 CL TECHNICAL MANUAL VER1 0 ACCESSORIES CONNECTION GUIDE 3021 3021...

Страница 8: ...PAGE 8 of 12 VRDK1 CL TECHNICAL MANUAL VER1 0 WIRING DIAGRAM...

Страница 9: ...the factory default procedure on the following page Enter a new engineers code or enter the same engineers code again followed by enter This code can be from 4 8 digits and will not activate a relay...

Страница 10: ...rom the keypad Step 2 Press and hold the enter button while re powering the keypad Step 3 Release the enter button The factory engineer s code is restored to 111111 6 x 1 Re Enter the engineer s code...

Страница 11: ...is should be there all the time and comes directly from the PSU Lock will not operate from telephone Check terminal 5 on the telephone This terminal shorts to terminal 3 of the telephone when pressed...

Страница 12: ...Unit 4 7 Chillingham Ind Est Newcastle Upon Tyne NE6 2XX TEL 0870 300 1240 FAX 0191 224 5678 Southern Office 1 Osprey Trinity Park Trinity Way London E4 8TD FAX 0208 523 5825 TECHNICAL SUPPORT tech v...

Отзывы: