EDITION 1.2 

VANDAL RESISTANT 

ONE BUTTON DOOR 

ENTRY KIT WITH CODED 

ACCESS 

VR4K-1/CL 

Содержание VR4K-1/CL

Страница 1: ...TECHNICAL MANUAL EDITION 1 2 VANDAL RESISTANT ONE BUTTON DOOR ENTRY KIT WITH CODED ACCESS VR4K 1 CL...

Страница 2: ...PAGE 2 of 12 VR4K 1 CL TECHNICAL MANUAL VER1 2...

Страница 3: ...h this kit The output for the lock is a dry contact relay so any other type of lock can be used with an appropriate PSU If this kit is to be used with a gate the dry contact output can be used to trig...

Страница 4: ...n 0V side LED Not used with this kit BSY Busy signal for use with multiple door systems Normally high 12V Low when busy 0V SL Switched 0V output to switch on video PSU 0V throughout a call open collec...

Страница 5: ...er supply or auxiliary power supply TELEPHONE Art 3111 CONNECTIONS Terminal Function 12 12Vdc output 200mA Max 8 8Vdc output 300mA Max 0V Ground 13Vac 1A Max 230 Mains in Live connection 0 Mains in Ne...

Страница 6: ...cess control cables must be routed separately from the mains When the panel is mounted on an uneven surface use additional sealant to protect from water ingress LOCK RELEASE 12V AC 0 1uF capacitor CAB...

Страница 7: ...L CARE The door panel is manufactured from 12 Gauge 304 grade stainless steel It is important that the facia is cleaned on regular occasions to prevent dirt build up and tarnishing of the metal A gene...

Страница 8: ...PAGE 8 of 12 VR4K 1 CL TECHNICAL MANUAL VER1 2 WIRING DIAGRAM...

Страница 9: ...follow the factory default procedure on the following page Enter a new engineers code or enter the same engineers code again followed by enter This code can be from 4 8 digits and will not activate a...

Страница 10: ...from the keypad Step 2 Press and hold the enter button while re powering the keypad Step 3 Release the enter button The factory engineer s code is restored to 111111 6 x 1 Re Enter the engineer s cod...

Страница 11: ...all the time and comes directly from the PSU Lock will not operate from telephone Check terminal 5 on the telephone This terminal shorts to terminal 3 of the telephone when pressed Becomes 0V and send...

Страница 12: ...Unit 4 7 Chillingham Ind Est Newcastle Upon Tyne NE6 2XX TEL 0870 300 1240 FAX 0191 224 5678 Southern Office 1 Osprey Trinity Park Trinity Way London E4 8TD FAX 0208 523 5825 TECHNICAL SUPPORT tech v...