background image

 
 
 

PAGE 9 of 12 

             VR4K-1/CL TECHNICAL MANUAL 

 

VER1.2 

VR4KCLM-1 CODELOCK  

 
The VR4KCLM-1 includes two relays (5A contacts), two push to exit inputs (Switched 
negative) and can have up to two 4 to 8 digit access codes programmed (One per relay). 
The relay times can be programmed from 01 second up to 99 seconds or by setting the 
relay time to 00, latch the relay (To latch, enter the code followed by enter and to unlatch 
enter the code followed by clear).  

 

INITIAL PROGRAMMING

 

 
All programming is carried out using the codelock keypad. The programming menu is 
protected by an engineer’s code. The factory default engineers code is 111111 (6x1). This 
code can be changed to any four to eight digit code during the program but must be 
different to the codes used to gain entry. Follow the flow chart to setup the system:- 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Enter the engineer’s 

code. 

111111 

Then press enter 

The red LED will illuminate to acknowledge programming mode. If the red 
LED does not illuminate check the master code is correct. If the master 
code may have been changed from the factory default and you do not 
know what it is then follow the factory default procedure on the following 
page. 

Enter a new engineers 

code or enter the same 

engineers code again 

followed by enter 

This code can be from 4 – 8 digits and will not activate a relay. It can only 
be used to enter programming mode. 
Note this new code in the box provided on the next page. It will be needed 
to re-program the codes in the future. 

Enter the access code 

for relay 1 and then 

press enter 

This code will be used to open the door/gate (Relay 1). The code can be 
from 4 – 8 digits long and must be different from the engineer’s code. 

Enter a two digit relay 1 

time from 00 – 99 and 

then press enter 

This is the time the relay 1 will energise for. 00 will latch the relay when 
the code is entered and require the code followed by clear to unlatch. 

Enter the access code 

for relay 2 and then 

press enter 

This code will be used to open the door/gate (Relay 2). The code can be 
from 4 – 8 digits long and must be different from the engineer’s code. 

Enter a two digit relay 2 

time from 00 – 99 and 

then press enter 

This is the time the relay 2 will energise for. 00 will latch the relay when 
the code is entered and require the code followed by clear to unlatch. 

More 

codes? 

YES 

NO 

Press enter twice 

The red LED will go off to confirm the exit from programming mode. 

Содержание VR4K-1/CL

Страница 1: ...TECHNICAL MANUAL EDITION 1 2 VANDAL RESISTANT ONE BUTTON DOOR ENTRY KIT WITH CODED ACCESS VR4K 1 CL...

Страница 2: ...PAGE 2 of 12 VR4K 1 CL TECHNICAL MANUAL VER1 2...

Страница 3: ...h this kit The output for the lock is a dry contact relay so any other type of lock can be used with an appropriate PSU If this kit is to be used with a gate the dry contact output can be used to trig...

Страница 4: ...n 0V side LED Not used with this kit BSY Busy signal for use with multiple door systems Normally high 12V Low when busy 0V SL Switched 0V output to switch on video PSU 0V throughout a call open collec...

Страница 5: ...er supply or auxiliary power supply TELEPHONE Art 3111 CONNECTIONS Terminal Function 12 12Vdc output 200mA Max 8 8Vdc output 300mA Max 0V Ground 13Vac 1A Max 230 Mains in Live connection 0 Mains in Ne...

Страница 6: ...cess control cables must be routed separately from the mains When the panel is mounted on an uneven surface use additional sealant to protect from water ingress LOCK RELEASE 12V AC 0 1uF capacitor CAB...

Страница 7: ...L CARE The door panel is manufactured from 12 Gauge 304 grade stainless steel It is important that the facia is cleaned on regular occasions to prevent dirt build up and tarnishing of the metal A gene...

Страница 8: ...PAGE 8 of 12 VR4K 1 CL TECHNICAL MANUAL VER1 2 WIRING DIAGRAM...

Страница 9: ...follow the factory default procedure on the following page Enter a new engineers code or enter the same engineers code again followed by enter This code can be from 4 8 digits and will not activate a...

Страница 10: ...from the keypad Step 2 Press and hold the enter button while re powering the keypad Step 3 Release the enter button The factory engineer s code is restored to 111111 6 x 1 Re Enter the engineer s cod...

Страница 11: ...all the time and comes directly from the PSU Lock will not operate from telephone Check terminal 5 on the telephone This terminal shorts to terminal 3 of the telephone when pressed Becomes 0V and send...

Страница 12: ...Unit 4 7 Chillingham Ind Est Newcastle Upon Tyne NE6 2XX TEL 0870 300 1240 FAX 0191 224 5678 Southern Office 1 Osprey Trinity Park Trinity Way London E4 8TD FAX 0208 523 5825 TECHNICAL SUPPORT tech v...

Отзывы: