CAMERA NOTES
MAXIMUM ILLUMINATION DISTANCE
FROM CAMERA AT NIGHT
The illumination LED’s within the camera
will illuminate the visitor when they are
within 50 cm of the camera.
MAX 50 cm
FIELDS OF VIEW
The fields of view for standard camera are 55° for vertical angle and 115° for horizontal angle
while for Wide Angle camera are 80° for vertical angle and 170° for horizontal angle.
195 cm
80° 55°
170 cm
100 cm
75 cm
135 cm
70 cm
Vertical angle
170°
115°
180 cm
105 cm
70 cm
Horizontal angle
Standard camera
Wide Angle camera
CONNECTION TERMINALS SIGNALS
ART. 4384 VERSIONS
VID2 Video signal input (coax centre core)
GNDV Video signal ground (coax screen and 0V to camera)
+V2
Output to supply the external camera
if necessary
Max 12Vdc
150mA
BUS
BUS Connection terminals
BUS
PTE
“Push to exit” active low input
GND
Ground
NO
Door open relay normally open contact Max 12-24
Vac/dc 2A
C
Door open relay common contact
+C
Electric lock capacitor discharge output
VAUX
35Vdc power supply input/output.
In case the use of Art. 2321, the module is powered
locally and not from the BUS.
It can be used as a source power (up to 20mA) to
drive the Art. 4846 module backlight.
NC
Door open relay normally closed
contact
Max 12-24
Vac/dc 2A
ART. 4384X VERSIONS
VID2 Video signal input (coax centre core)
GNDV Video signal ground (coax screen and 0V to camera)
+V2
Output to supply the external camera
if necessary
Max 12Vdc
150mA
BUS
BUS Connection terminals
BUS
PTE
“Push to exit” active low input
GND
Ground
NO
Door open relay normally open contact Max 12-24
Vac/dc 2A
C
Door open relay common contact
+C
Electric lock capacitor discharge output
VAUX
35Vdc power supply input/output.
In case the use of Art. 2321, the module is powered
locally and not from the BUS.
It can be used as a source power (up to 20mA) to
drive the Art. 4846 module backlight.
NC
Door open relay normally closed
contact
Max 12-24
Vac/dc 2A
GND
Ground
B
RS-485 serial interface
A
CLEANING OF THE PLATE
Use a clean and soft cloth. Use moderate warm water or non-ag-
gressive cleansers.
Do not use:
• abrasive liquids;
• chlorine-based liquids;
• metal cleaning products.
TECHNICAL SPECIFICATIONS
Call buttons:
Up to 94
Power consumption:
Stand-by:
60+10mA for each 404x
Operating 100+10mA for each 404x
Peak:
250mA
Working voltage:
Supplied by the BUS line
Working temperature: -20 +60 °C
Art. 4384
Speaker unit with built-in camera
Art. 4384X
Speaker unit with built-in camera & proximity key reader