TERMINAL CONNECTIONS
Terminal
Description
NO1
Normally open 1 relay contact.
Relay 1, 2 and 3 contacts:
3A@24Vdc
3A@120Vac
CO1
Common 1 relay contact.
NC1
Normally closed 1 relay contact.
NO2
Normally open 2 relay contact.
CO2
Common 2 relay contact.
NC2
Normally closed 2 relay contact.
NO3
Normally open 3 relay contact.
CO3
Common 3 relay contact.
NC3
Normally closed 3 relay contact.
+
+12Vdc power input (500mA max.)
–
0V ground power.
A1
Auxiliary 1 input (triggers relay 1 when A1 mode set to 000, switched 0V, default).
A2
Auxiliary 2 input (triggers relay 2 when A2 mode set to 000, switched 0V, default).
A3
Auxiliary 3 input (triggers relay 3 when A3 mode set to 000, switched 0V, default).
A
RS485 bus connection (for ease of programming and permanent connection for monitoring purposes).
B
GND
L
BUS line data input.
–
BUS line ground input.
STATUS INDICATION LED’S
LED
Description
During ‘power up’ the red LED (LED1) will flash continuously while trying to connect the Art.2270
module to the network. As soon as the module is connected to the network it will switch OFF. The
LED will also switch ON whenever the line is in use or the module is busy and will flash whenever the
network connection is lost and is trying to re-establish a connection.
The green LED (LED2) will flash whenever it sees data on the
L
and
-
bus connection (when the Art.2270
module is in use). The LED will switch ON and stay ON during communication via the USB or RS485 bus
connection. In standby when the module is not in use the LED will be switched OFF.
TECHNICAL SPECIFICATION
Working Voltage
: 12Vdc +/- 10%
Standby Current
: approx. 60mA
Max. Current
: approx. 500mA (max.)
Phone ID’s (call buttons)
: 1 up to 180 (max.)
Telephone Numbers per ID
: 4 telephone numbers (1 primary, 3 diverts)
Dial to Open Numbers
: up to 1000 per relay (max.), 3000 DTO numbers in total
Status Indication LED’s
: 2 (red LED1 power up/busy, green LED2 data)
Programming
: SMS messaging or PC software
Auxiliary Inputs
: 3 (A1, A2 and A3 switched 0V input)
Dry Contact Relay
: 3 (relay 1, 2 and 3), 3A @ 24Vdc, 3A @ 120Vac
Event Log
: up to 8000 events
USB Port
: micro USB
RS485 Bus Connection
: A, B and GND
Timebands
: 1 programmable timeband
Dimensions
: 157.5mm (W) x 85mm (L) x 65mm (D)
Working Temp.
: -10 +50
o
C
Technical Information