background image

66250862-EN - V4.0 - 15/03/19

- 13 -

VK8K/6758 Series “6 wire Bus” videokit

VK8K/6758 Series - Installation handbook

INSTALLING A FLUSH MOUNTING DOOR STATION

1.  Mount back box 

S

 (Fig. 2)

 at 165 cm from ground level 

(Fig. 1)

;

2.  If more than one flush box is needed, connect them by using the plastic spacers provided 

A

 (Fig. 2)

;

3.  If necessary finish and clean properly the module support fixing holes and all other holes 

B

 (Fig. 2)

;

4. A rainshield 

D

 (Fig. 3 & 4)

 can be mounted using the fixing screws 

G

 (Fig. 4)

 to conceal possible wall finishing defects and 

protect against rain;

In order to prevent water ingress we highly recommend using a silicon sealant between the wall and the back box 
and between the wall and the rainshield 

D

 (Fig.3);

5.  Remove the fixing screws 

H

 (Fig. 5)

 and remove the plastic cover 

E

 (Fig.  5)

 of the module support;

6.  Insert the modules 

F

 (Fig. 6)

 according the required configuration;

7.  Insert the microphone of the door unit amplifier into the microphone hole 

X

 (Fig. 7)

;

8.  Secure the modules by refitting the plastic cover 

E

 (Fig. 8)

 and using the screws 

H

 (Fig. 8)

;

9.  Insert the hinge 

I

 (Fig. 9)

 and fix it with the two screws 

K

 (Fig. 9)

 provided;

10. Make all connections following accurately the wiring diagram provided. Check the installation and if necessary adjust speech 

levels using volume controls 

L

 (Fig. 9)

;

11. Lever the support 

R

 (Fig. 10)

 upwards and fix it to the back box with the screw 

M

 (Fig. 11)

 using an alan key 

P

 (Fig. 11)

;

12. Conceal the screw using the plastic cover 

N

 (Fig. 11)

 provided.

INSTALLING A SURFACE MOUNTING DOOR STATION

Fix the surface box on the wall at a distance of 165 cm between the top of the box and the ground 

(Fig. 1).

In order to prevent water ingress we highly recommend using a silicon sealant between the wall and the back box 

J

 

(Fig.12) and around all holes 

W

 (Fig.12).

To complete the installation follow the same steps described above for the flush box.

Note: if additional holes are made in the box or rainshield, oxidation problems may appear unless the 
unprotected metal is coated with a protective paint.

HOW TO REMOVE THE CARD NAME HOLDER

• 

To avoid damage to the module front plate, tape the side that will be in contact with the screwdriver blade;

• 

lnsert a flat screwdriver into the card-holder hole as shown in 

Fig. 13;

• 

Move the screwdriver to the left as shown in 

Fig. 14 

to extract the card name holder;

• 

Edit the card name then replace it inside the holder and refit: insert the holder inside its housing from the left or right side then 
push the other side until it clips into place.

8000 Series 

 Surface and flush mounting door station installation

Содержание 6758

Страница 1: ...03 19 VIDEOKIT VK8K 6758 SERIES 6 Wire bus one way two way videokit Installation handbook VK8K VK8KC We recommend This equipment is installed by a Competent Electrician Security or Communications Eng...

Страница 2: ...show how to connect a 12Vdc electric lock these directions are suitable for all diagrams in this manual Eachtimeasettingischangedonavideophone address extension numberofringsetc thevideophonemustbedi...

Страница 3: ...Art 8855 Flush mounting box 1 Art 8875 Rainshield 1 Colour videophone Art 6758 1 Power supply Art 850K VK8K 1S 6758 surface mounting 1 Outdoor station composed of 1 Art 8833 1 1 button camera unit 1...

Страница 4: ...shield 1 Colour videophone Art 6758 1 Power supply Art 850K VK8KC 1S 6758 surface mounting 1 Outdoor station composed of 1 Art 8833 1 1 button camera unit 1 Art 8800 Codelock module 1 Art 8887 Surface...

Страница 5: ...ions then restore the mains CABLE SIZE Video connections and Audio connections must be wired in twisted pair pair the video lines terminals signals V1 and V2 pair the audio lines terminals signals 1 a...

Страница 6: ...the conversation it is not possible to open the door but the key LED on the door station switches on for the program med time Incorrect position of J2 jumper Electriclockwiresunconnectedorinshort Wro...

Страница 7: ...SW Switch 3 Conversation Time OFF 60 seconds ON 120 seconds SW Switch 4 Door opening time J2 L position OFF 2 seconds ON 6 seconds JUMPERS J1 J2 J3 J1 Reassurance tone volume Low J1 Reassurance tone...

Страница 8: ...s Fig 6 Using separate P S U SIGNALS TERMINALS NO Door open relay normally open contact Max 24Vdc 3mA when used as dry contacts relay NC Door open relay normally closed contact C Door open relay commo...

Страница 9: ...best results from the schematics described it is necessary to install only original VIDEX equipment strictly keeping to the items indicated on each schematic and follow these General Directions for In...

Страница 10: ...TEM TO PRESET ENGINEER S FACTORY CODE Turn off power to code lock Keep ENTER button pressed while turning the power back on Release ENTER button The engineer s code is now set to 111111 six times one...

Страница 11: ...is relay 2 and third loop is relay 3 Only for Art 8800 3 ART 8800 CONNECTION TERMINALS SIGNALS SW1 Relay 1 command signal active low SW2 Relay 2 command signal active low NC2 Relay 2 normally closed...

Страница 12: ...Fig 2 E H Fig 5 H E Fig 8 M P N Fig 11 Fig 14 D Fig 3 F Fig 6 L K I Fig 9 W J Fig 12 12 VK8K 6758 Series 6 wire Bus videokit VK8K 6758 Series Installation handbook EXAMPLE INSTALLING A TWO MODULE OUTD...

Страница 13: ...ng diagram provided Check the installation and if necessary adjust speech levels using volume controls L Fig 9 11 Lever the support R Fig 10 upwards and fix it to the back box with the screw M Fig 11...

Страница 14: ...OUND open collector 24Vdc 100mA max while the button remain pressed Privacy ON OFF button When the system is in stand by the pressing of this button activates LED switched on or disables LED switched...

Страница 15: ...idly release the button to listen LED will flash slowly If the button is not pressed for 10 seconds the videomonitor will switch off The videomonitor will revert to duplex speech when another call is...

Страница 16: ...20Vdc Input Output As input 16 20Vdc 0 5A as output 20Vdc 0 5A max Ground reference for V terminal 1 Speech line output from microphone and data signal Approx 12V in stand by 5V during a conversation...

Страница 17: ...Fig 4 If you use the flush mounting box 503 embed it into the wall vertically at approx 140cm from the finished floor and the base 4 Following Fig 4 make the holes B insert the wall plugs C and fix th...

Страница 18: ...In white plastic ABS box 11x70x30mm surface mount ART 316N As Art 316 but small form factor without terminals to connect plus and minus from videophones is required an external connection of these te...

Страница 19: ...h 002 dwg 07 02 2017 27 02 2017 Local Bell Push to Exit Door Monitor Art 8833 1 Using Electric Lock 12Vdc 0 3A Max Con serratura elettrica 12Vdc 0 3A Max Art 8833 1 In caso di modifica alle impostazio...

Страница 20: ...sing Electric Lock 12Vdc 0 3A Max Con serratura elettrica 12Vdc 0 3A Max Art 8833 2 In caso di modifica alle impostazioni dei dip switch del videocitofono o del posto esterno togliere temporaneamente...

Страница 21: ...nte l alimentazione di rete In order to make the system recognize any modification of the videophone s and outdoor station s dip switch setting temporarily disconnect the system from the mains and rec...

Страница 22: ...t 8833 2 Art 8800 Using Electric Lock 12Vdc 0 3A Max Con serratura elettrica 12Vdc 0 3A Max Art 8833 2 In caso di modifica alle impostazioni dei dip switch del videocitofono o del posto esterno toglie...

Страница 23: ...h 006 dwg 07 02 2017 27 02 2017 Local Bell Affinche qualsiasi modifica alle impostazioni dei dip switch del videocitofono o del posto esterno venga riconosciuta dal sistema necessario togliere l alime...

Страница 24: ...togliere temporaneamente l alimentazione di rete In order to make the system recognize any modification of the videophone s and outdoor station s dip switch setting temporarily disconnect the system f...

Страница 25: ...66250862 EN V4 0 15 03 19 25 VK8K 6758 Series 6 wire Bus videokit VK8K 6758 Series Installation handbook Installation diagrams VIDEOKIT VK8KC 1 6758 VK8KC 1S 6758 WITH 3 ADDITIONAL VIDEOPHONES...

Страница 26: ...ock 12Vdc 0 3A Max Con serratura elettrica 12Vdc 0 3A Max Art 8833 2 In caso di modifica alle impostazioni dei dip switch del videocitofono o del posto esterno togliere temporaneamente l alimentazione...

Страница 27: ...rt 8833 2 ID 2 Art 8833 2 ID 1 Push to Exit Push to Exit 18Vdc 230V ART 323 18 20V GND 1 2 V1 V2 Videx Electronics S p A Via del Lavoro 1 63846 Monte Giberto FM Phone 39 0734 631669 Fax 39 0734 631669...

Страница 28: ...66250862 EN V4 0 15 03 19 28...

Страница 29: ...66250862 EN V4 0 15 03 19 29...

Страница 30: ...66250862 EN V4 0 15 03 19 30...

Страница 31: ...unicipauxenm lange L utilisateurdoitdoncremettrel quipementenfinde vieauxcentresdecollecteappropri soulerestitueraurevendeurlorsdel achatd unnouveautyped quipement quiva lent danslerapportdeun un Depl...

Страница 32: ...Center Twente BCT Grotestraat 64 NL 7622 GM Borne www videxintercom nl info videxintercom nl El producto lleva la marca CE que demuestra su conformidad y puede ser distribuido en todos los estados mi...

Отзывы: