66250862-EN - V4.0 - 15/03/19
- 10 -
VK8K/6758 Series “6 wire Bus” videokit
VK8K/6758 Series - Installation handbook
Art. 8800 - Art. 8800-3
Digital codelock module
PROGRAMMING
• Enter
ENGINEER’S CODE
: first time type six times
1
(
111111
factory preset) and press ENTER (The red LED will illuminate).
• Confirm
ENGINEER’S CODE
(typing again the same) or
type the new code (4 to 8 digits) then press
ENTER
(Melo-
dy). Pressing twice the
ENTER
button without changing the
ENGINEER’S CODE
, will exit from the programming.
• Enter the code (4 to 8 digits) to enable
RELAY 1
(ACCESS 1) or
re-enter the existing code then press
ENTER
(Melody).
• Enter the
RELAY 1
operation time (2 digits 01 to 99
I.E.
05=5
seconds, 00= remain open time) or re-enter the existing time
then press
ENTER
(Melody).
• Enter the code (4 to 8 digits) to enable
RELAY 2
(ACCESS 2) or
re-enter theexisting code then press
ENTER
(Melody).
• Enter the
RELAY 2
operation time (2 digits 01 to 99
I.E.
05=5
seconds, 00=remain open time) or re-enter the existing time
then press
ENTER
(Melody).
• Enter the code (4 to 8 digits) to enable
RELAY 3
(ACCESS 3
only for Art. 8800-3) or re-enter the existing code then press
ENTER
(Melody).
• Enter the
RELAY 3
(only for Art. 8800-3) operation time (2 dig-
its 01 to 99
I.E.
05=5 seconds, 00=remain open time) or re-en-
ter the existing time then press
ENTER
(Melody).
• The system is ready to use (the red LED will be off ).
RETURN SYSTEM TO PRESET ENGINEER’S FACTORY CODE
• Turn off power to code lock;
• Keep
ENTER
button pressed while turning the power back on;
• Release
ENTER
button;
• The engineer’s code is now set to
111111
(six times one).
OPERATION
To use the system, type in the programmed code and press
ENTER
, the green LED will illuminate and the relay will operate for the
programmed time.To cancel remain open time, type in the same code and press
CLEAR
. If a wrong code is entered, a continuous
melody will sound for 4 or more seconds, according to the number of mistakes.
OPERATION NOTES
• To operate relays together, set the same code for each relay;
• If a wrong code is entered, the system will lock out for 5 seconds which will increase each time a wrong code is entered. The system will
operate only when the correct code is enter
ENTER THE
"ENGINEER’S CODE"
CONFIRM
OR CHANGE
"ENGINEER’S CODE"
ENTER
"ACCESS 1 CODE"
ENTER
"ACCESS 2 CODE"
ENTER
"ACCESS 3 CODE"
***
ENTER
"ACCESS 1 TIME"
ENTER
"ACCESS 2 TIME"
ENTER
"ACCESS 3 TIME"
***
SYSTEM
READY TO USE
First time six times
1 “111111” factory
preset
Type again six times
“1” or the new en-
gineer’s code 4 to 8
digits
Code to enable relay 1
4 to 8 digits
Code to enable relay 2
4 to 8 digits
Code to enable relay 3
4 to 8 digits
Two digits (01 to 99)
i.E. 05=5 Seconds
00= remain open
Two digits (01 to 99)
i.E. 05=5 Seconds
Two digits (01 to 99)
i.E. 05=5 Seconds
Red led will be off
Press Enter
(Red LED will
be ON)
Press Enter
(melody)
Press Enter
(melody)
Press Enter
(melody)
Press Enter
(melody)
Press Enter
(melody)
Press Enter
(melody)
Press Enter
(melody)
*** Only for Art. 8800-3
Содержание 6758
Страница 28: ...66250862 EN V4 0 15 03 19 28...
Страница 29: ...66250862 EN V4 0 15 03 19 29...
Страница 30: ...66250862 EN V4 0 15 03 19 30...