4000 Series Vandal Resistant Range

Art. 4212V-4212RV - Installation instructions

FLOOR

The floor field displays the floor number of the user called. It is available only in 

NORMAL MODE 

and can be any value from “1” to “250”.

Modify routine

•  select user searching by name or flat

•  press 

“4” 

to enter into edit mode;

•  type floor number;

•  press   to save or   to delete characters or exit edit mode without save.

ENABLE

It specifies whether User is enabled or not. If a visitor tries to call a disabled user typing the flat number, display will show 

“NOT 

FOUND” 

otherwise the intercom for that flat will be called. Intercom specified by Phone Id and Block Id.

Modify routine

•  select user searching by name or flat;

•  press 

“5” 

to enter into edit mode;

•  press 

“5”

 to enable or disable;

•  press   to save or   to exit edit mode without save.

PHONE ID

The phone ID represents the address of the intercom to call (Set by the 8 way dip switches in the intercom).

Modify routine

•  select user searching by name or flat;

•  press 

“6” 

to enter into edit mode;

•  type Phone Id number;

•  press   to save or   to delete characters or exit edit mode without save.

BLOCK ID

Block Id field specifies the address of Art. 2206N. It can assume values from “1” to “15”. This field is visible only if the panel is set to 

MAIN MODE 

(see 

“Panel mode” on pag. 13

).

Modify routine

•  select user searching by name or flat;

•  press 

“7” 

to enter into edit mode;

•  type Block Id number;

•  press   to save or   to delete characters or exit edit mode without save.

TAG

The tags (key or fob) allow users to open the door. Three fob code lengths are supported (2, 3 & 4 bytes). It is specified by Tag width 

parameter (see 

“Fob width” on pag. 15

).

User can be linked to more than one access code. The modify routine is described in 

“Key managing” on pag. 6

 

Art. 4212V - 4212RV 

 Audio/video digital front panel 

Programming

Содержание 4212RV

Страница 1: ...alanced V1 V2 Coax V2 V V1 not used Balance V PB CHIP Made in Italy 12T GNDV V2 V V1 PTE TRD NO C NC SL BS L 12 GND OC OUTPUT D0 D1 LR LG WIEGAND A B GND RS485 Dry contact output Capacitor discharge R...

Страница 2: ...era provides the best quality of view in any light condition and the wide angle camera provides a viewing angle of 170 degrees The camera can be set to work with composite video signal coax cable or b...

Страница 3: ...n door if enabled see Trade on pag 12 a valid Access code the door will be open or NOT FOUND message will appear To delete digits or exit page press HOW TO CALL AN APARTMENT From stand by mode enter a...

Страница 4: ...nctions to scroll back to scroll forward to alternate between capital and lower case letters For instance to type the name VIDEX it is necessary to press 3 times 8 button V 3 times 4 button I 1 times...

Страница 5: ...n COMPATIBILITY MODE please refer to User parameters Code on pag 7 From Programming menu press 1 to enter the user menu then 1 to modify a user find the user by name or flat press 3 and enter in User...

Страница 6: ...usly select search by key option he has to pass card fob over the symbol if searched key is present the user tag modify page will appear pressing 1 to enable disable the key press to save or to exit w...

Страница 7: ...ve or to delete characters or exit edit mode without save FLAT The flat number is entered by the visitor to call a flat It can be 1 to 6 digits long Modify routine select user searching by name or fla...

Страница 8: ...edit mode without save PHONE ID The phone ID represents the address of the intercom to call Set by the 8 way dip switches in the intercom Modify routine select user searching by name or flat press 6 t...

Страница 9: ...en in standby Enter the string and press The have a blank line enter one or more space characters Modify routine press 1 2 or 3 to enter into edit mode enter the string press to save or to delete char...

Страница 10: ...o switch from 1 12 to 0 23 and viceversa press to save or to exit edit mode without saving CLOCK Set the time on the door panel Modify routine press 1 to enter the clock menu press 2 to enter edit mod...

Страница 11: ...ess 3 to enter the trade menu press 1 to enter edit mode press 1 to enable or disable the facility press to save or to exit edit mode without saving TRADE START TRADE END The beginning and end times o...

Страница 12: ...nd and only when TRD is shorted to 0V It must be between 3 to 6 digits and different to all other codes Entering the correct code when the above requirements are met will open the door for the program...

Страница 13: ...ave or to delete characters or exit edit mode without saving MASTER Specifies if the panel is a master or a slave On each bus there should only be one master all other panels on that bus should be sla...

Страница 14: ...memory location PROXIMITY ACCESS MODE This parameter specifies if the proximity reader works in a self contained standalone mode or is connected via a Wiegand interface to an external controller such...

Страница 15: ...called is pronounced singularly i e 123 one two three In COMBINED mode number called is pronounced all in one i e 123 one hundred and twenty three Modify routine press 2 to enter into edit mode press...

Страница 16: ...CTION TERMINALS JUMPERS Dry contact output Capacitor discharge SWITCHES Balanced V1 V2 Coax V2 V V1 not used RS485 BUS TERMINATION Open Close CONNECTION TERMINALS 12T 12Vdc Camera power supply unit GN...

Страница 17: ...66250203 EN V0 3 10 07 15 17 4000 Series Vandal Resistant Range Art 4212V 4212RV Installation instructions Art 4212V 4212RV Audio video digital front panel...

Страница 18: ...66250203 EN V0 3 10 07 15 18 4000 Series Vandal Resistant Range Art 4212V 4212RV Installation instructions Art 4212V 4212RV Audio video digital front panel...

Страница 19: ...out hole in the box 2 Make all the connections on the removable terminal blocks Fig 2 then plug back into the panel Fig 3 setup the dip switches as per provided connection diagram or instruction sheet...

Страница 20: ...ox fix surface box to the wall using the screws G Fig 3 4 Connect the wires using a terminal screw driver then setup the dip switches as per provided connection diagram or instruction sheet then power...

Отзывы: