4000 Series Vandal Resistant Range
Art. 4212V-4212RV - Installation instructions
SYSTEM SETTINGS
System par. menu Parameter Name
Programming method
Permission
Default value
1: Language
Language
By panel and PC software
Only Engineer
English
2: ID
ID
By panel and PC software
Only Engineer
1
3: Master
Master
By panel and PC software
Only Engineer
Enabled
4: Panel mode
Panel mode
By panel and PC software
Only Engineer
Local
Security Level
Only by PC software
/
Fob or Code
Mode
Only by PC software
/
Compatibility mode
Enable Direct Call
Only by PC software
/
Disabled
Proximity Access Mode
Only by PC software
/
Stand alone mode
LANGUAGE
Languages supported are: English, Italian, Spanish, Portuguese, French, German, Czech, Croatian, Danish, Polish and Slovenian.
Only user messages change language, the programming menu’s are always in English.
Modify routine
• press
“1”
to enter into edit mode;
• press
“1”
repeatedly to scroll through the available languages;
• press to save or to exit edit mode without saving.
ID
The panel ID came be from 1 to 15. Each panel on a system should have a unique ID.
Modify routine
• press
“2”
to enter into edit mode;
• Enter the panel ID from 1 to 15;
• press to save or to delete characters or exit edit mode without saving.
MASTER
Specifies if the panel is a master or a slave. On each bus there should only be one master, all other panels on that bus should be slaves.
Modify routine
• press
“3”
to enter into edit mode;
• press
“3”
to enable or disable;
• press to save or to exit edit mode without saving.
PANEL MODE
Specifies if the system includes the 2206N bus exchange devices or not and if the panel is a main panel or a local panel. If there are no
2206N devices on the system then this setting should be LOCAL. If there are 2206N devices on the system and this panel is a main en-
trance calling all apartments then this setting should be MAIN. If the panel is a block entrance panel then this setting should be LOCAL.
Modify routine
• press
“4”
to enter into edit mode;
• press
“4”
to switch from
LOCAL
to
MAIN
and viceversa;
• press to save or to exit edit mode without saving.
SECURITY LEVEL
Art. 4212 can work in two different security modes: Fob or Code and Fob + Code.
In Fob or Code, key and code are linked only with user. Insertion of enabled code or passing a key over the reader will open the door.
In Fob + Code, key and code are linked together. Single code is linked with single key.A user must enter a code and present a key to
open the door. Parameter can be changed only through PC programming routine.