PROGRAMMING
TO ENTER PROGRAMMING MODE
From standby mode:
• press
“0”
to enter the coded access mode;
• enter the Master code (with engineer permissions - see
) or Admin code (with limited permissions - see
);
• press to enter the code or to delete characters or exit access code mode;
• if entered code isn’t stored in memory, panel will show
“NOT FOUND!”
.
ADDING USERS
From Programming menu (
):
• press
“1”
to enter the user menu;
• then press
“2”
to add a new user;
• The adding a new user routine is different depending on on if the panel mode is
COMPATIBILITY MODE
or
NORMAL MODE
:
» In
COMPATIBILITY MODE
, user can add fields in following order:
NAME -> FLAT -> CODE -> FLOOR -> ENABLE -> PHONE -> BLOCK (only in
MAIN
MODE
);
» In
NORMAL MODE
:
NAME -> FLAT -> FLOOR -> ENABLE -> PHONE -> BLOCK (only in
MAIN MODE
);
• At the end of the routine the system checks if the user can be saved to memory.
New item is invalid when Phone ID and Block ID are equal to another one in memory and the flat number doesn’t match. In this
case a
“ALREADY IN MEMORY”
message will appear.
To modify users please refer
CODE MANAGEMENT
This routine is only valid in
NORMAL MODE
. When in
COMPATIBILITY MODE
, please refer to
From Programming menu:
• press
“1”
to enter the user menu then
“1”
to modify a user.;
• find the user by name or flat;
• press
“3”
and enter in User Code menu;
HOW TO ADD A CODE
• press
“3”
to add a code;
• insert code;
• if code is not already in memory, display will show
“ITEM SAVED”
, or
“ALREADY IN MEMORY”
with corresponding acoustic signals.
Note:
if in Code + fob mode. Adding a code will automatically be followed by inserting a fob.
HOW TO MODIFY A CODE
• press
“1”
to modify a code;
• insert code. If searched code is present, panel enters user Code modify page;
• press
“1”
to enable or disable code;
• press
“2”
to edit the code;
• type access code;
• press
to save or to delete characters or exit edit mode without saving. If code is not already in memory, display will show
“ITEM SAVED”
, else
“ALREADY IN MEMORY”
with corresponding acoustic signals.
HOW TO DELETE A CODE
• press
“2”
to enter in User Code Delete menu;
• press
“1”
to delete single item or
“2”
to delete all codes linked with selected users;
» if user has previously selected the
“All”
option, panel will delete all codes linked with selected user and
“DELETED MESSAGE”
will appear;
» if user has previously selected
“Single”
the panel will enter the User Code Search:
› if searched code is present, panel will show
” ITEM SAVED”
message;
› if searched code isn’t present in memory, panel will show
“NOT FOUND!”
.
QUICK CALL
This feature allows the user to set a favorite user (only one) to be called quickly by simply pressing the button.
The call will begin only if the selected user is enabled (see
user parameter
).
NOTE
: this function is only available for Art. 4212RV, Art. 4212RV/F, Art. 4212RV/SA and Art. 4212R.