66250203 - V4.4 - 15/05/22
- 7 -
4000 Series Vandal Resistant Range
Art. 4212 - Installation instructions
PROGRAMMING PARAMETERS
USER PARAMETERS
User par. menu
Parameter Name Programming Method
Permission
Default value
1: Usr
User name
By panel and PC software
All
“ “
2: Flat
Flat
By panel and PC software
All
/
3: Code
Code
By panel and PC software
All
/
4: Fl.
Floor
By panel and PC software
All
/
5: En.
Enable
By panel and PC software
All
Enabled
6: Ph. Id
Phone Id
By panel and PC software
Only Engineer
/
7: Bl. Id
Block Id
By panel and PC software
Only Engineer
/
8:Tag
Tag
By panel and PC software
All
/
USER NAME
The user name can be up to 16 characters long and is displayed
during searching and calling.
Modify routine
• select user searching by name or flat;
• press
“1”
button to enter into edit mode;
• type name;
• press
to save or to delete characters or exit edit mode
without save.
FLAT
The flat number is entered by the visitor to call a flat. It can be 1
to 6 digits long.
Modify routine
• select user searching by name or flat;
• press
“2”
button to enter into edit mode;
• type flat number;
• press
to save or to delete characters or exit edit mode
without save.
CODE
Access Code is entered by the user to open the door.
Modify routine depends on Mode setting: in
COMPATIBILITY
MODE
only one code is possible per user. Pressing
“3”
will allow
the code to be edited.
In
NORMAL MODE
multiple codes can be assigned to a user.
This routine is described in
In both cases codes can be from 3 to 6 digits using keys 0 - 9. It
can be disabled by leaving it blank.
Modify routine (only for COMPATIBILITY MODE)
• select user searching by name or flat;
• press
“3”
to enter into edit mode;
• type new access code;
• press
to save or to delete characters or exit edit mode
without saving.
FLOOR
The floor field displays the floor number of the user called. It is avail-
able only in
NORMAL MODE
and can be any value from “1” to “250”.
Modify routine
• select user searching by name or flat
• press
“4”
to enter into edit mode;
• type floor number;
• press
to save or to delete characters or exit edit mode
without save.
ENABLE
It specifies whether User is enabled or not. If a visitor tries to call
a disabled user typing the flat number, display will show
“NOT
FOUND”
otherwise the intercom for that flat will be called. In-
tercom specified by Phone Id and Block Id.
Modify routine
• select user searching by name or flat;
• press
“5”
to enter into edit mode;
• press
“5”
to enable or disable;
• press to save or to exit edit mode without save.
PHONE ID
The phone ID represents the address of the intercom to call (Set
by the 8 way dip switches in the intercom).
Modify routine
• select user searching by name or flat;
• press
“6”
to enter into edit mode;
• type Phone Id number;
• press
to save or to delete characters or exit edit mode
without save.
BLOCK ID
Block Id field specifies the address of Art. 2206N. It can assume
values from “1” to “15”. This field is visible only if the panel is set
to
MAIN MODE
(see
Modify routine
• select user searching by name or flat;
• press
“7”
to enter into edit mode;
• type Block Id number;
• press
to save or to delete characters or exit edit mode
without save.
TAG
The tags (key or fob) allow users to open the door. Three fob
code lengths are supported (2, 3 & 4 bytes). It is specified by Tag
width parameter (see
).
User can be linked to more than one access code. The modify
routine is described in
Art. 4212