PROGRAMMING
The programming of the unit can be carried out from the panel keypad or a PC via RS-232 serial connection and the PC programming software. The
programming step 6.3 is only available if the panel is programmed as “MAIN” (main door panel in a system with main entrance and secondary entrances
using Art.2306 exchangers). On systems with main and secondary entrances, panels at the main entrances must be set as “MAIN” while panels at the
block entrances must be set as “STAND.” (standard). The main door panels call all the apartments on the system so for each apartment the block ad-
dress (2306 address) must be programmed in addition to the device address.
PROGRAMMING VIA PANEL KEYPAD
Prg.
Step
Display Operation
1
ENTER FLAT NR.
OR SEARCH
The panel is in stand-by
Press “0” button
2
CODE:******
Type the ENGINEER’s code (factory default six times “1”) to access to the programming menù (the display will
show a star for each digit typed).
Press “ENTER”
3
CODE:******
NEW:
If required type a new ENGINEER’s code (up to 6 digits).
Press “ENTER”
4
TRADE C.: xxxx
NEW:
Type the new TRADE CODE (up to 6 digits)
1
or leave unchanged (if existing).
Press “ENTER”
5
0 = STAND. 1=MAIN
0 NEW:
Type 0 if the panel is used on system with 1 or more entrances on the same level or on secondary entrances on
systems with main and secondary entrances. Type 1 if the panel is used as main entrance on a system with
main entrances and secondary entrances.
Press “ENTER”
6
MEM.LOCATION:
Type a memory location to program (1..998)
2
or nothing to jump to programming step 6.
Press “ENTER”
6.1
FLAT:ffffff
NEW:
Type the new “FLAT CODE” (up to 6 digits) or leave unchanged (if existing). The “FLAT CODE” is the number
used by the visitor to call the flat by typing the number into the door panel keypad and pressing enter.
Press “ENTER”
6.2
ID PHONE:iii
NEW:
Type the new “ID PHONE” (up to 3 digits)
3
or leave unchanged (if existing). The “ID PHONE” is the ID of the unit
(intercom or videophone) located inside the flat.
Press “ENTER”
6.3
ID BLOCK:bb
NEW:
Type the new “ID BLOCK” (2 digit) or leave unchanged (if existing). The “ID BLOCK” is the ID of the block (set on
the Art.2306 relative to the block) to which the unit (intercom, videophone or relay) is connected. This setting is
available only when main mode is set..
Press “ENTER”
6.4
DOOR CODE:dddddd
NEW:
Type the new “DOOR CODE” (up to 6 digits) or leave unchanged (if existing). The “DOOR CODE” is the code
that allows the user to open the door from the outside by typing it in at the door panel keypad. (Pressing CODE
followed by the code and then enter).
Press “ENTER”
6.5
USER NAME:
uuuuuuuuuuuuuuuu
Type the new “USER NAME” (up to 16 characters) or leave unchanged (if existing). The “USER NAME” is the
name shown when the visitor use the repertory name facility (only on 4302R)
Press “ENTER”, the programming goes back at the beginning of point 6
7
SPEECH TIME:sss
Type the new “SPEECH TIME” (up to 3 digits in seconds) or leave unchanged (if existing). This is the duration of
the conversation time. When the speech time expire the conversation is automatically closed.
Press “ENTER”
8
DOOR TIME:ddd
Type the new “DOOR TIME” or leave unchanged (if existing). This is the duration of door open relay actuation.
The relay will activate for the time specified by this value.
Press “ENTER”
9
DEVICE n:n
Type the new “DEVICE NO” or leave unchanged (if existing). This is an unique identifier for the panel. It is used
for camera recall operation (see videophone instructions)
Press “ENTER”
10
1=ENG, 2=IT, 3=ESP
4=POR, 5=FR, 6=GER
The display shows the selected language by the relevant number underlined. Type the number relevant to the
required language or leave it unchanged.
Press “ENTER”
11
1=NO, 2=ST, 3=CMB
SPEECH BOARD
The display shows the selected speech board operation mode
4
by the relevant number underlined. Leave un-
changed or type the number relevant to the operating mode required.
Press “ENTER”
12
TEST MODE:
1-2, ENTER=END
Choose the required test mode
5
to test or press “ENTER” to exit programming
Notes
1
The trade code is the door opening code reserved to periodic visitors like postman, milkman etc. The trade code only works if the TRD input is
shorted to ground.
2
Memory locations “0” and “999” are reserved to store respectively the “stand-by logo” and the “switched logo” that are two message of 16 charac-
ters each that are alternatively shown on the display when the unit is in stand-by mode. These messages may be customized to provide help to
the visitors.
3
The ID PHONE is the binary address of the unit set on the 8 way dip-switch.
4
In mode one the speech board is disabled, in mode 2 the numbers are said digit by digit while in mode 3 the numbers are said as per pronuncia-
tion.
5
Each of the 2 test modes make a call to the intercoms/videophones stored in memory to check if it answers.
In mode 1 the unit performs a quick test without switching on the intercoms/videophones and exits the test when the first error is encountered (the
display shows the related error code (see table below). In mode 2 it makes the same tests as mode 1 but when an error is encountered it is sig-
nalled for 5 seconds with the error code then the test continues until all apartments are tested.
Содержание 2301N Kristallo Series
Страница 1: ...2 5 Edition 2010 Rev 2 9 ...
Страница 2: ......
Страница 44: ...PrtCode VX2300_2_9 doc Pag 44 08 03 2011 Rev 2 9 VIDEO DOOR ENTRY SYSTEM FOR N USERS WITH BUS BOOSTER ART 2315 ...
Страница 52: ...PrtCode VX2300_2_9 doc Pag 52 08 03 2011 Rev 2 9 5 ENTRANCES 4 USERS VIDEO DOOR ENTRY SYSTEM ...
Страница 53: ...PrtCode VX2300_2_9 doc Pag 53 08 03 2011 Rev 2 9 5 ENTRANCES 4 USERS VIDEO DOOR ENTRY SYSTEM ...
Страница 57: ...NOTEs ...
Страница 58: ...NOTEs ...
Страница 59: ......