Digital Recorder
46
For a Videoswitch modem, the baud rate should be 115200.
PSTN rings
If a modem is being used, specify here how many rings should occurs before the DVR
answers the call.
[^][v] Set number of ring
[TAG] Set default
RS232 Baud Rate
If the DVR is to be remotely controlled via an RS232 cable, the baud rate may be set here.
For use with a modem the rate should be 115.2K baud.
[^][v] Set baud rate
[TAG] Set default
9.7 Configuration
This part of the menu deals with basic configuration of the DVR that is normally carried out
only during installation.
Multi unit configuration
Some Videoswitch DVRs may be linked to produce larger systems. In this case each has to
be programmed with a unit number and the total number of linked units.
In a multi-unit configuration, cameras are called up on a remote keyboard by entering the
required camera number 1 to 256. The user does not see the boundary between units.
From a configuration point of view, each unit is treated separately, and settings can be
different on each unit as required.
Unit Number
Multiple DVRs may be linked to provide a system with more than 16 cameras. Cameras 1 to
256 may then be called up using a remote keboard.
In multi-unit configurations, give each unit in the linked chain a unique number, starting at 1
for the master and incrementing by one for each subsequent unit.
In single-unit installations, set the unit number to none.
[^][v] set unit number
Number of Linked Units
Multiple DVRs may be linked to provide a system with more than 16 cameras. Cameras 1 to
256 may then be called up using a remote keboard.
In multi-unit configurations, each unit should be told the total number of inter-connected
units in this option:
[^][v] set number of linked units
Simultaneous Control
If this option is set, in a multi unit configuration, all units will switch between live and play
mode simultaneously.
If this option is not set, each unit can be controlled independently.
Intelligent Security and Fire Ltd