6. Inspection Standard
6.1. Inspection environment conditions
Room Temperature: 20~25°
Humidity: 65±5% RH
6.2. The viewing line should be perpendicular to the surface screen.
Dot defect
a) Inspection condition
Inspection distance: 35±5cm
Inspection illumination: 100~150Lux
Panel temperature: 30±5
Inspection pattern: Full white, full black, red, green and blue screens.
b) Acceptable
Area
Item
A B
Total
Blue
Black
2 3 4
Red Green White
1
3
3
Total
2 5 7
c) The definitions of A and B zone
B
A
V/2 V/4
V
H/4 H/2
H
Scratch on the polarizer
Number = 3 max.
Width 0.1 mm, Length 6 mm
Dent on the polarizer
Number = 3 max, Average Diameter
∅
0.3 mm
Foreign material on the polarizer
Number = 2 max, Average Diameter
∅
0.5 mm
Afterimage
After displaying a pattern for 5 seconds then switch to a different pattern, the previous
pattern should disappear within 10 seconds.
Doc # 45M17
Issue Date: 11/09/05
Revision: B