3. Measurement Specifications
*Standard Measurement Condition and Measurement Procedure
See
“ APPENDIX 2 ”
4. Environment Condition And Test
Operating Condition
Temperature -10°C ~ 50°C (Recommended: -5°C ~ 40°C)
Humidity
10% ~ .85%
Storage Condition
Temperature -20°C ~ 60°C
Humidity
0% ~ 90%
High Temperature storage Test
Leave the camera packed at a temperature of 60°C for 72 Hours. Then bring it to room
temperature and leave it for 8 Hours. There should be no problem in performance.
Low Temperature storage Test
Leave the camera packed at a temperature of -20°C for 72 Hours. Then bring it to room
temperature for 8 Hours. There should be no problem in performance.
5. Interface
Pin Assignment
J3, 10 Pin Connector; Maker Molex/Yeon-ho, 12505WR-10A00
* Is the color of the cable. (If offered)
PIN No.
NAME
I/O
* Color Note
1
C - OUT
Output White
2
Y - OUT
Output Gray
3
GND (For Video)
Violet
4 VIDEO
OUT
Output
Blue
5
DC IN (ALIVE)
Input
Green
9 V ~ 15 V (Recommendation 12
±
0.5 V)
6 KEY
1
Input
Yellow
7 KEY
2
Input
Orange
8
DD ON
Output Red
For Video Presenter
9 POWER
ON Input
Brown
10
GND (For Power)
Black
Pin Assignment
J2, J10, 3 Pin Connector; Maker Molex/Yeon-ho, 12505WR-03A00: R/C Receiver
J2
J10
Pin No. NAME
I/O
3 DC
OUT Output
2
GND (For R/C)
1 R/C
DATA Input
Pin No. NAME
I/O
1 DC
OUT Output
2
GND (For R/C)
3 R/C
DATA Input
Doc # APN 20/21Z704USB
Issue Date: 05/11/2007
Revision: C
Page 8 of