Installation manual XV 

 

8

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
** For GPRS transmission, the panel will  
send alarms and videos to IP 1 (or DOMAIN NAME1) / PORT1 
 or for backup transmission to IP 2 (or DOMAIN NAME 2) 
 / PORT 2 ** 

 

YES

 

CODE/STATE modification 

 
These are the default transmitted events: 
 

Intrusions 
Panic 
Periodic Test 
Tamper 
Supervision Fault 
Device Battery Low 
Panel Battery Low 

 
If you would like any other events to be transmitted press  

  YES  and  use  the   

  or 

  to  toggle  between 

events. 
 
If you would like the default press ESC/NO 
 
 

CODE/STATE 

MODIFICATION ? 

TRANS. STATE 
MODIFICATION 

List of all 

events 

YES

 

ESC/NO 

TRANS. STATE 
MODIFICATION 

ESC/NO 

ESC/NO 

Your  IP1  address  is  given  to  you  by  your  monitoring 
Station

.   

Press 

 YES to enter into the parameter and use the  

Keypad to complete the address.  Press 

 YES to confirm  

your entry and the 

 arrow to move to the next parameter.   

 
*You will use either a IP address or a Domain Name but not  
Both* 

The Port is given to you by your Central Station

.   

 
By  default  the  panel  will  use  888. If  you  need to  modify the 

port press the  

  YES key to enter into the parameter and 

the keypad to complete the port.  Press 

 YES to confirm 

and the 

 arrow to move to the next parameter.

 

Your  Domain  Name  is  given  to  you  by  your  Central 
Station. 

Press  

 YES to enter into the parameter and use the  

Keypad to complete the name.   

Press  

 YES to confirm your entry and the  

 arrow to 

move to the next parameter.  
 
*You will use either a IP address or a Domain Name but not  
Both. Leave it blank if an IP has already been entered.* 

Press 

 to configure IP2 (or DOMAIN NAME 2)  and PORT 

2 for the back-up server, and IP TMT (or DOMAIN TMT) and 
PORT TMT to configure remote maintenance server. 
 

IP1 ADRESS 

 

IP1 ADRESS: 

xxx.xxx.xxx.xxx 

DOMAIN NAME 1 

 

DOMAIN NAME 1: 

xxxxx.xxx.xxx 

PORT 1 

 

PORT 1: 

xxx 

YES

 

YES

 

 

 

YES

 

SERVER 

ADDRESSES? 

YES

 

ESC/NO 

SERVER 

ADDRESSES? 

ESC/NO 

Содержание XV

Страница 1: ......

Страница 2: ...adio range The XV can also have two wired speaker microphone units for full duplex audio verification Supervised Wireless Technology The XV GPRS along with all Videofied devices uses the patented S2View Interactive AES Encrypted Wireless technology providing optimum signal integrity and security The bi directional RF communication path between all devices and the system control panel guarantees hi...

Страница 3: ... XV Programming 5 3 XV Panel 11 4 TP200 Speakers Microphone 12 5 Configuration 13 6 Level test GPRS error 17 7 Specials codes 17 8 Programmable Wired Inputs 18 9 Mapping Function 18 10 Programmable Wired Output 19 11 XV Power Values 20 12 XV Wireless Devices 20 15 XV Datasheet 21 ...

Страница 4: ...DOES NOT HAVE TO BE PERFORMED IN ORDER TO PROGRAM THE PANEL How to Mount the Control Panel Fix the back casing on the wall with 3 screws to Open the Control Panel Use a screwdriver unscrew the 2 screws holding the panel together Install the SIM card Put the SIM card on the plastic base Take care to respect the right direction Slide it into the connector ...

Страница 5: ... panel is now in Learn Mode for the CMA200 keypad Insert all three batteries into the CMA200 and press on both the ESC NO and CLR keys at the same time and release The indicator LED on the keypad will blink rapidly Other languages are available by scrolling with arrows ITALIANO NEDERLANDS DEUTSCH CASTELLANO SVENSKA PORTUGUES FRANCAIS Press YES for the selected one YES CLR ESC NO or for language se...

Страница 6: ...airing with the control panel This test is the strength of communication between the device and the control panel The keypad will display a real time range out of 9 for the device that the test is running for To receive the most accurate results you must run the radio range test for at least 30 seconds The RF level test must be 8 9 or better for reliable transmission Wait while the screen changes ...

Страница 7: ...ric Keypad to enter in a 4 8 digit account number provided by the Central Station YOU MUST ALWAYS CHOOSE YES Using the arrow keys YES to choose the Hour and Minute the periodic test will happen or for period selection and YES to apply YES YES YES YES YES TIME Minutes 15 00 TIME Minutes 15 15 11 10 01 15 15 ENTRY COMPLETE CONNECTED TO MONITOR STATION ACCOUNT NUMBER 99865123 PERIODIC TEST 24 HOURS D...

Страница 8: ...ow to move to the next parameter You will use either a IP address or a Domain Name but not Both The Port is given to you by your Central Station By default the panel will use 888 If you need to modify the port press the YES key to enter into the parameter and the keypad to complete the port Press YES to confirm and the arrow to move to the next parameter Your Domain Name is given to you by your Ce...

Страница 9: ... PARAMETERS APN CODE APN CODE xxxxx xxxxxx xxx USER NAME PASSWORD PASSWORD xxxxxxxxxxxx USER NAME xxxxxxxxxxx YES YES YES YES GPRS PARAMETERS ESC NO ESC NO Once you have entered all valid parameters press ESC NO to return to the main menu then ESC NO again to move to the next parameter GPRS LEVEL TEST IN PROGRESS YES END GPRS LEVEL x 5 YES YES During the GPRS Level test the Modem will boot and att...

Страница 10: ... device you would like to program Before completing programming make sure that all tampers are depressed by verifying that each devices indicator LED is off Other values are available 2 min 1 min 45 sec Use the arrows for the selection and YES to confirm Others values are available 2 min 1 min 45 sec 30 sec 15 sec Use the arrows for the selection and YES to confirm Enter the name of the logical ar...

Страница 11: ...d user The programming customization can give you many combinations of video voice inputs and outputs to match all of your customers needs XV Features Two Programmable inputs and one programmable output and have a mapping function that allows you to trigger a video from a Videofied Motion Viewer upon any event Two dedicated connectors to extend the GPRS and Radio range Two wired speaker microphone...

Страница 12: ...re connected Maximum combined length 40 m if the first TP200 is 30 meters far from the panel the maximum length of the second cable for 2 nd TP200 will be maximum 10 meters On the panel s end strip the wire s cladding on at least 1cm for a proper contact to be established In case of acoustics problems The TP200 module has to be fixed to the wall to eliminate vibrations The TP200 module has to be f...

Страница 13: ...From 999898 to 999999 All codes 1 From 314157 to 314159 All codes 2 A total of 186 codes are forbidden Access level Codes and badges get rights access to one of the 4 available levels of access Access level Definition rights LVL1 Stand by level LVL2 Restricted USER level where it is only possible to arm disarm the system LVL3 USER level where it is possible to arm disarm the system check the event...

Страница 14: ...n alarm Areas 1 2 3 4 Each time you press the corresponding number the system will toggle the arming States A A A A state for the respective area Press the YES key after this configuration step The system will then display what siren mode will be in effect for this special profile Select the siren mode using the direction arrows then press YES 5 3 GPRS Parameters To configure or modify the GPRS pa...

Страница 15: ...monitoring parameters go to CONFIGURATION YES MONITORING CONFIGURATION YES PARAMETERS YES In this menu you have Monitoring Enable or Disable Account Number provided by your monitoring station Server addresses parameters provided by your monitoring station Calling Profile Three options are available Strategy ETH GPRS GPRS for Back up ETHERNET ONLY GPRS ONLY Sequence Alternating test with alternatin...

Страница 16: ...4 YES AREAS AND DEVICES YES SCHEDULING YES Scheduling Enable Enable all scheduled tasks Calendar Management In this menu you are able to create new scheduled tasks To create a new scheduled task press YES OK Use the or to set the Hour Use the or to set the minutes Use the or to set ARM close or DISARM Open Select the day press 1 for Monday 2 for Tuesday 7 for Sunday Several days can be select for ...

Страница 17: ...IM card has to be deactivated or 00000 7 Specials codes Codes Action 999999 Maintenance request GPRS transmission 999997 Give the information that the panel detects main power or not 999991 The panel will send a test alarm to the first IP address configured in the menu Address Server In case of failure the panel will not stay blocked in transmission Very long time This code can be use just to test...

Страница 18: ...ll transmit a panic event 9 Mapping Function The mapping function is available on the XV panel configuration With this option it is possible to ask for one DCV200 or DCV250 a ten video second on event or when a programmable input triggered Cf Appli note_Prog_Input Example of an application using the mapping a panic button is connected to the wired programmable input when the end user press the pan...

Страница 19: ...ut One wired programmable output is available on the XV IP panel To use and configure this programmable output please read the application note Prog_Output Example of an application using the programmable output on intrusion trigger a spot light for 3 minutes ...

Страница 20: ...1 Installation manual XV 20 11 XV Power Values Below is the table of values accepted by the XV panel 12 XV Wireless Devices Compatibility The XV GPRS works with all the following Videofied wireless devices ...

Страница 21: ...ormation Programming Alphanumeric Keypads Devices per system 25 per system Access codes 20 maximum Arming modes 2 Number of areas 4 History Event Log 4 000 events stored in flash memory Communicator Communicator type GPRS Protocol Frontel IP stack TCP IP VIdeo transmission By Frontel protocol to central monitoring station GPRS antenna Integrated External GPRS antenna Yes via MMCX connector Video V...

Отзывы: