Videofied XTO Series Скачать руководство пользователя страница 11

11

INSTALLATION MANUAL

3.

XTO-IP

 

PANEL PROGRAMMING

XTO-IP 

Alarm panel

SERVER

ADDRESSES ?

The

 IP1 address

,

 

Domain name 1

 and/or 

Port 1

 are provided by the monitoring station.

 

Leave Port details at 888 unless otherwise instructed.

 

Press 

OK

 or 

YES

 to enter/modify the parameter then 

OK

 or 

YES

 for validation.

WARNING : You will use either an 

IP address

 or a 

Domain name 

but

 not both

, leave the

 

Domain name

 blank if an 

IP address

 has already been entered.

Press on the right arrow to configure IP/Domain name 2 and PORT2 (for the back-up server), 

and IP/Domain name TMT and PORT TMT (to configure remote maintenance server).

ESC

NO

OK 

or 

YES

ESC

NO

STRATEGY:

ETH+2G3G

4G

2G3G

4G

 

PARAMETERS ?

ESC

NO

OK 

or 

YES

TEST IN PROGRESS

END = OK/YES

2G3G

4G

 LEVEL

5/5

2G3G

4G

 LEVEL ?

2G3G

4G

 LEVEL ?

OK 

or 

YES

The 

APN Code

 (Access Point Name), 

User Name

 and 

Password

 are supplied by the 

mobile operator. Please make sure you have entered the code exactly as indicated by your 

local SIM card operator.

Press 

OK

 or 

YES

 to enter/modify the parameter then 

OK

 or 

YES

 for validation.

Note: When entering your SIM card settings, both APN codes, username and 
password fields are case sensitive! It makes a difference between UPPER and lower 
case letters.

To switch between UPPER and lower case, use the M/m key from CMA keypad or hold a digit key 

(0-9) for XMA/XMB.

Once the 2G3G

4G

 test completed, the keypad will display one of the following results :

-  A level between 0/5 and 5/5.

-  A GPRS Error code (please see Chapter 7 : 2G3G

4

G

 errors codes and contact your 

technical support). 

If the screens shuts down, press any key to light it up except 

OK

 or 

YES

ESC NO

 or 

CLR

.

The 2G3G

4G 

level test can last several minutes.  Do not interrupt the test or remove the SIM 

card during the test.

IMPORTANT : Videofied will require a 3/5 grade or better for reliable transmission 
of Video alarms.

ESC

NO

2G3G

4G 

PARAMETERS ?

OK 

or 

YES

How the alarms and videos are transmitted to the monitoring station ?

ETH+2G3G

4G

 : Ethernet transmission with GPRS backup.

2G3G

4G

 : GPRS transmission only (if the Ethernet connection is not used).

ETH : Ethernet transmission only (only if GPRS is not used).

Warning : the transmission mode “Ethernet only” is not recommended.

ESC

NO

IP1 ADDRESS 

0.0.0.0

DOMAIN NAME 1

PORT 1

888

APN CODE

internet-entrepr

USER NAME

orange

PASSWORD

orange

Содержание XTO Series

Страница 1: ...XTO XTO IP ALARM PANEL SERIES INSTALLATION MANUAL DOC REF 230 XTO IP MODIF DATE SEPTEMBER 2018 FIRMWARE VERSION XLP 04 04 00 XXX AND LATER 1 ...

Страница 2: ...chnology ensuring signal integrity and optimal security Thereliabilityofthesignalisguaranteedthankstothetwo wayradiofrequencytransmissionswithalltheperipherals of the Videofied product line The integrated antennas allow the system to be totally wireless thus preventing from the system beeing inelegant and cumbersome and eliminating the installation problems The jamming detection feature identifies...

Страница 3: ...ETHERNET parameters configuration 12 XTENDER mode configuration 14 4 XTO iP features guide 16 4 1 Get to access level 4 16 4 2 How to Arm Disarm the system 16 4 3 Arming and Siren Mode Configuration 17 4 4 Manage badges and access codes 18 4 5 Delete the keypad or any other device 20 4 6 Read the event log 21 4 7 Programmable inputs and outputs 21 4 8 Golden rules 22 5 Transmitted events list 23 6...

Страница 4: ...bracket the latter beeing used to attach the panel to the wall or a pole Mounting the panel is not required for programming Screwholes 1 1 SIM card installation Before removing the front cover from its box Put the SIM card on the plastic base Take care to respect the right direction DO NOT insert or remove the SIM card while the panel is powered ...

Страница 5: ...teries at once Mixing new and used batteries can severely damage the panel risk of explosion Press and hold the PROGRAMMING BUTTON for 10 seconds until the indicator LED blinks twice The panel is now reset a CMA XMA or XMB has to be enrolled to configure the panel Programmingbutton MainsPowerSupply Lithiumbatteries DonotuseLithiumbatterieswhenthepanelismainspowered WhenusingEthernet onlypoweryorpa...

Страница 6: ...play one of the following screens 1 4 Pairing the remote keypad RSI c 2013 videofied com XX or Press on both CLR and ESC NO keys at the same time and release The indicator LED on the keypad will blink rapidly Wait for the keypad to pair If the keypad doesn t pair up with the panel and shows XX it certainly means that it is still paired to another system and needs to be reset Take the batteries out...

Страница 7: ...n also be connected to an existing alarm system capable of latching a 9 12Vcc voltage used for its arming disarming When the panel is used in XTENDER mode the system will only be able to arm and disarm by latching 9 12Vcc to its arming inputs Arming Input 1 and or Arming Input 2 When the voltage switches to 0V the panel will disarm automatically On a programmed panel you can choose between standal...

Страница 8: ...his test measures the strength of communication between the device and the control panel The keypad will display a real time radio range value on a scale of 9 To receive the most accurate results you must run the radio range test for at least 30 seconds Result must be 8 out of 9 or better for reliable transmission Using the Alphanumeric Keypad enter the Installer Code of your choice The Installer ...

Страница 9: ...is used it cannot be set later the system must be defaulted Leaving the name blank by pressing ESC NO it will be named ACCESS 1 by default Please wait ADJUSTING DATE AND TIME DATE YEAR 12 To set the year OK orYES DATE MONTH 13 01 To set the month OK orYES You may proceed in the same way for Day Hour and Minutes 13 10 14 10 47 ENTRY COMPLETE ACCOUNT NUMBER CONNECTED TO MONITOR STATION OK orYES Use ...

Страница 10: ...ATION Keypad display Actions and comments The CODE STATE MODIF menu is to configure the transmitted events to the monitoring station use the arrow keys to toggle between events and OK or YES to modify ALARM event transmitted upon occurrence ALARM END event is transmitted on occurrence and on event restoral NOT TRANSMITTED event is not transmitted however it will appear on the keypad Please liaise ...

Страница 11: ... Note When entering your SIM card settings both APN codes username and password fields are case sensitive It makes a difference between UPPER and lower case letters To switch between UPPER and lower case use the M m key from CMA keypad or hold a digit key 0 9 for XMA XMB Once the 2G3G4G test completed the keypad will display one of the following results A level between 0 5 and 5 5 A GPRS Error cod...

Страница 12: ...ther Ethernet parameters with the arrows ETHERNET OFF NO STATUS the Ethernet module is switched off Please verify that the Ethernet cable is connected and try again NETWORK CABLE MISSING the panel doesn t detect Ethernet Cable or Network BysettingtheDHCPasENABLED a new IP address will be assigned dynamically to the panel every time it connects to the network Network parameters will not be asked If...

Страница 13: ...MS AREAS CONFIGURATION AREA 1 NAME ESC NO OK orYES OK orYES OK orYES ARMING PROFILE STANDALONE ARMING PROFILE FROM THE HOST EXIT DELAY 45 sec For the selection OK orYES ENTRY DELAY 15 sec For the selection Pleasegotopage15ifyouchose STANDALONE OK orYES Pleasegotopage14ifyouchose FROMTHEHOST For full compatibility with EN50131 press OK or YES Otherwise press ESC NO Press ESC NO to default the area ...

Страница 14: ...40 0 _ Arming Confirmation is the number of seconds the system will wait to arm after voltage is latched on the arming input This feature can be used as an exit delay we suggest you to enter the same value as your master system exit delay Enter the value you would like for the Arming Confirmation and press OK or YES OK orYES ARMING MODE MODE SLOW MODE FAST OK orYES OK orYES OK orYES The transmissi...

Страница 15: ...O After initial programming has been completed the system cannot be armed or disarmed until a user code or badge is entered the installer code cannot arm or disarm the system Press OK or YES to register one or more badges ESC NO if you re not using any badges If you wish to use an user code please skip this step and when initial programming is completed go to the BADGES ACCESS CODES menu please re...

Страница 16: ... your user code and press OK orYES Press press OK orYES and enter your user code With remote badge reader BR250 N A Present your badge on the badge reader N A N A With remote keyfob N A N A Press Press 4 1 Get to Access level 4 Tue 29 10 11 23 DISARMED LVL 1 ACCESS LEVEL 1 ACCESS LEVEL LEVEL 1 ACCESS LEVEL LEVEL 4 OK orYES OK orYES To unlock and get access to the installer level 4 you need to succ...

Страница 17: ...is special profile Select the siren mode using the direction arrows then press OK YES A Armed D Disarmed P Perimeter bydefault allopeningcontacts E External bydefault allopeningcontacts withexternalaccess You can set your devices as External Perimeter ou External Perimeter Please go to the menu CONFIGURATION LVL 4 AREAS AND DEVICES DEVICES DEVICES CONFIGURATION DEVICE TYPE Siren Immediate triggeri...

Страница 18: ...est the devices Modifications of the settings are not possible at this level User Level 3 can create Level 2 or Level 3 access codes or badges LVL 4 INSTALLER level where it is possible to modify the setup of the panel To access Level 4 the approval of a Level 3 oe Level 2 user is required Installer Level 4 can create the first Level 3 access code only How to return to the LVL1 After 1 min of no u...

Страница 19: ...e is created 1000 for example the 2 next codes and previous codes 0998 0999 1001 and 1002 will be automatically reserved The 1 code 1001 is used for disarming under duress The 2 code 1002 is used for panic The 1 and 2 codes 0998 et 0999 are reserved to prevent conflicts when creating a new user code Reserved Codes 000000 From 9998 to 9999 From 99998 to 99999 From 999898 to 999999 From 314157 to 31...

Страница 20: ...ce You can now remove the batteries from the device ACCESS LEVEL 4 CONFIGURATION GENERAL PARAMETERS OK orYES to select the device and press OK orYES XX DELETE AREAS AND DEVICES DEVICES ADD A NEW DEVICE DEVICE CONFIGURATION A1 KEYPAD KEYPAD 1 OK orYES OK orYES OK orYES Devices list OK orYES OK orYES ...

Страница 21: ... The XTO iP control panel also offer a mapping feature Mapping option allows the input to generate a video clip via a MotionViewer when a programmable input is triggered and or when an event occurs For further information about the programmable inputs and outputs please consult the following application notes available on our support website 240 XV XT PROG INPUTS APP NOTE 240 XV XT PROG OUTPUTS AP...

Страница 22: ... protect an access and not a zone 8 Do not fix the keypad at the beginning of the installation as it will need to be portable during programming Always clean the lens of the cameras after the installation Use a clean dry cloth taking care not to exert pressure on the lens 9 10 To switch between UPPER and lower case use the M m key from the CMA keypad or hold a digit key 0 to 9 for XMA XMB 11 Inter...

Страница 23: ...ATE MODIFICATION Use the arrows to access CONFIGURATION level4 CONFIGURATIONMONITOR STATION MONITORINGPARAMETERS EVENTTRANS MODIFICATION Then use the arrows to determine the event to modify Press OK or YES to edit These are the default transmitted events DEVICE intrusions ALERT Panic Buttons PANEL LOW BATT TAMPER DEVICE LOW BATT PERIODIC TEST DURESS CODE FIRE MEDICAL ASSIST ETHERNET CABLE AC POWER...

Страница 24: ...des are subject to change by SIM card operators However the GPRS level test errors results in the majority of cases have the following causes SIM Card activation Delay Some operators require an additional delay up to 48 hours to activate automatic data transmission Please check with your operator prior to installation APN CODE USERNAME and PASSWORD The GPRS 2G3G4G settings are supplied by the oper...

Страница 25: ...nts IC établies pour un environnement non contrôlé Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps This transmitter must not be co located or operating in conjunction with any other antenna or transmitter This device complies with Part 15 of the FCC Rules and with RSS 210 of Industry Canada Operation is subject to the ...

Страница 26: ...a South America 902 907 5MHz 915 928MHz FHSS XTO iP 830 Brazil Transmission security AES encryption algorithm Radio jam detection Yes Supervision Yes Radio antenna Integrated External radio antenna Option with MMCX connector Programmable wired inputs Number 3 Dry contact Yes Input voltage 12 VDC 15VDC max Programmable wired outputs Number 2 Max switching voltage 24VDC 30VAC Max switching current 1...

Страница 27: ...t By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health The recycling of materials will help to conserve natural resources For more information about recycling of this product please contact your local municipality your waste disposal service or the company that installed the product XTO iP 630 902 928 MHz FHSS ...

Отзывы: