Videofied OSMVC 200 Скачать руководство пользователя страница 6

6

INSTALL SHEET

OSMVC

 OUTDOOR STREAMING MOTION VIEWER

Sensitivity adjustment

The OSMVC detector comes with the capability of adjusting the sensitivity level of the PIR. It can improve the 
detection or, on the contrary, reduce false alarms. Raising sensitivity will raise detection range, the detection 
field will be larger and smaller thermal signatures will be detected. You should only use this feature when the 
site has been diagnosed as needing this adjustment. It cannot be used to optimize detection as the adjustment 
may be too high and generate either false alarms or missed intrusions.

Examples : Plant growth, pets.

Please note that the detector must be installed to prevent intrusions (aim the detector towards an access 
point), sensitivity adjustment will have no effect if the installation doesn’t comply with the installation 
recommendations described in this document.

Adjust sensitivity for the OSMVC MotionViewer

To change the OSMVC sensitivity, you need to change the 

detector name

:

DEVICE

CONFIGURATION

CHANGE NAME 

DEVICE

OK 

or 

YES

To select the OSMVC

OK 

or 

YES

Enter the detector name then enter the 

$

 symbol at the end and the chosen digit 

(without space). The number following $ will depend on the necessary adjustment:

SENSITIVITY 

ADJUSTMENT

MINIMAL 

SENSITIVITY

detector_name

$2

LOW SENSITIVITY

detector_name

$1

DEFAULT 

SENSITIVITY

detector_name

HIGH SENSITIVITY

detector_name

$8

MAXIMAL 

SENSITIVITY

detector_name

$9

$ Symbol

CMA keypad

 : Press @ repeatedly until $ is displayed

XMA/XMB keypad

 : Press 

1

 

repeatedly until $ is displayed

Содержание OSMVC 200

Страница 1: ...tall the detector and other system devices in the order of the following steps Programming RF Testing program detector and all other devices into the control panel and test RF communication from each intended device location to the control panel Mounting mount detector at the tested location Mounting Use proper tools and hardware Mount camera between 2 5 m to 3 5 m height The OSMVC MotionViewer de...

Страница 2: ...ontinuously or you receive a 9 9 indicating good communication with the control panel 9 Press OK YES to end radio range test then press ESC NO 10 The keypad displays AREA ALLOCATION AREA 1 Press either arrow button repeatedly until desired area number appear then press OK YES By default all devices in Area 1 are automatically delayed 11 The display shows NAME LOCATION Enter appropriate device name...

Страница 3: ...ng or reducing the tilt even slightly has a big impact on the detection distance and on the blind area under the MotionViewer We recommend to slightly tilt the OSMVC to reduce its detection range and avoid false alarms To precisely determine the tilt angle use a smartphone app like Smart Protector Android or Pitch Gauge iOs Blind angle Max detection distance Tilt Mounting height Max detection dist...

Страница 4: ...ion If the TAMPER event is set as ALARM END a tamper restoral event is sent to the panel Longitudinal axis rotation Transverse axis rotation Tilt tamper disabling only for OSMVC version 07 06 04 XX and later The OSMVC Motionviewer must be deleted from the panel memory to disable tamper 1 Delete the OSMVC from the device configuration menu 2 Press and hold the OSMVC initialization button for 5 seco...

Страница 5: ...presence of water or moist surfaces Speed and direction of the movement OSMVC setup tilt height sensitivity Important It is essential to monitor the proper functioning of the infrared detection using the FUNCTIONAL TEST feature in the panel MAINTENANCE menu A red status LED lights up when the OSMVC is detecting Use that test to determine the pattern of the detection field Status LED Blind angle De...

Страница 6: ...alled to prevent intrusions aim the detector towards an access point sensitivity adjustment will have no effect if the installation doesn t comply with the installation recommendations described in this document Adjust sensitivity for the OSMVC MotionViewer To change the OSMVC sensitivity you need to change the detector name DEVICE CONFIGURATION CHANGE NAME DEVICE OK orYES To select the OSMVC OK o...

Страница 7: ...ever there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation be...

Страница 8: ...g height 2 5 m to 3 5 m Mounting angle 5 to 10 Mounting Use mounting kit sold separately Environmental data Operating temperature 25 70 C Max relative humidity 95 without condensing Protection marking IP 65 IK 06 Power requirements Type C 4 Lithium batteries 3 6 V LS14500 Battery life Standard usage up to 5 videos per month 4 years High usage about 30 videos per month 2 years Standby current consu...

Страница 9: ...ol on the product or on its packaging indicates that this product should not be treated as household waste It must be handed over to the applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health The recycling of materials will help ...

Отзывы: