Videofied IMD 200 Скачать руководство пользователя страница 2

Programming/RF Testing/Mounting

The following provides summarized steps for device programming, 
testing, and mounting. For complete details, refer to the control panel 
installation manual.

Loosen bottom screw.   1   

   Separate base from IMD.  2

Install 1 SAFT LS14500 3.6v batteries, observing correct  

 

      polarity. 

Put control panel into programming/configuration mode.

Using a programmed alphanumeric keypad, proceed through 

menus until the display shows ADD A NEW DEVICE.

Press Yes. The display shows PRESS PROGRAM BUTTON OF 

DEVICE.

Press and release program button on the IMD using your finger 

or a screw driver   1  .  The programming button is located inside the 
product on the top of the main PCB.   

 

 

    

The IMD LED flashes red   2  

.

 
 

Press Yes. The display shows RADIO RANGE TEST? Press Yes 

again. The IMD LED starts flashing and keypad display shows TEST IN 
PROGRESS.

Move  the  IMD  to  the  intended  mounting  location  and  make  sure                 

you receive a 9/9 indicating good communication with the control 
panel.

 
   

Press YES to end the Radio Range Test, then press ESC/NO.

10 

The display shows AREA ALLOCATION; AREA:  1.  Press either 

arrow button on the keypad until the desired AREA number appears, 
then press YES.  By default all devices in area 1 will be subject to the 
entry and exit delays.

11  

The display shows NAME + LOCATION:

Enter an appropriate device name (up to 16 characters).  The name of 
the device should describe its intended mounting location or zone.  
Press YES.  The display will show the device number and name for your 
verification.

12  

Mount the IMD on the wall:

Follow the mounting rules on page 1

Drill desired mounting holes in the IMD base and mark the 

appropriate mounting holes on the wall. 

Drill pilot holes and install anchors where needed.

 

Place base on mounting surface so that the pilot holes line up and 

secure base with appropriate screws.

Attach detector to base and secure with screw if required.

13 

Press YES.  The display shows FUNCTIONAL DEVICE TEST?     

Press YES again and verify IMD operation.  For example,   

 

wave your hand in front of the sensor to activate the LED   
which indicates detection.

14 

Press YES to end the detection verification

15 

The display shows ADD A NEW DEVICE? Repeat steps 1-14 for   

remaining Devices.

16  

When finished, exit from configuration mode by pressing and  

  holding the ESC/NO for 5 seconds.

 

 

 

 

 

Wait for keypad display to show DETECTOR (1 - 24) PROGRAMMED. 

 

 

 

*Check that the LED flashes before staying RED

 

 

1

1

2

2

I N S T A L L A T I O N   S H E E T

Indoor MotionViewer 

IMD 

200/601/701

www.videofied.com

Содержание IMD 200

Страница 1: ... Install the detector and other system devices in the following order Programming RF Testing Program detector and all other devices into the control panel and test RF communication at each intended devicelocationtothecontrolpanel Mounting Mountdetectoratthetestedlocation Mounting Rules Usepropertoolsandhardware Mountindoorsinatemperaturecontrolledenvironment Mountdetector2 1to2 3m 6 9to7 5ft fromt...

Страница 2: ...on the keypad until the desired AREA number appears then press YES By default all devices in area 1 will be subject to the entryandexitdelays 11 ThedisplayshowsNAME LOCATION Enter an appropriate device name up to 16 characters The name of the device should describe its intended mounting location or zone PressYES Thedisplaywillshowthedevicenumberandnameforyour verification 12 MounttheIMDonthewall F...

Страница 3: ...ce to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving ante...

Страница 4: ... Dimensions LxWxD 2 75 x 2 x 1 5in 51 2 x 80 9 x 36 8mm Weight 3 oz 58 g without battery Installation Mounting Mounting Height 2 1 to 2 3m 6 5 to 7 5ft Mounting on Wall On Flat Wall With 2 x Screws In Corner With 2 x Screws Closing of the Casing Closing by clip and screw if required by local legislation Certifications standards 868MHz IMD200 Standards EN60950 1 2006 A11 2009 A1 2010 EN300220 1 V2 ...

Отзывы: