1500 -4600W Model (5000-12000BTU/h Model)

5000-5100

Model

W

(17000-18000BTU/h Model)

Connect diagram

(21000-36000BTU/h Model)

6000-10000W Model

2

L N

N

L

Black

Indoor unit terminal

Blue

Connecting
cable

Brown

Yellow/Green

Blue

Brown

Black

Blue

Brown

Gray

N

L3

L2

2

L1

L

N

L

3

2

4

5

R1

6

R2

Outdoor unit

terminal

!"#$

Yellow/Green

POWER
SOURCE

N

Blue

N

Blue

POWER
SOURCE

L

Brown

L

Brown

Cool only type

Heat pump type

(T3)

(T3)

Indoor unit terminal

Outdoor unit

terminal

Black

Yellow/Green

2 N

2

N

Connecting
cable

Indoor unit terminal

Gray

Blue

Yellow/Green

3

2

N

3

2

N

4 R1R2

4

Brown

Blue

Brown

Brown

Cool only type

Heat pump type

Plug housing 1

Plug housing 1

Blue

Cool only type

OR

Connecting
cable

Outdoor unit terminal

Brown

Yellow/Green

Blue

3

2

N

3

2

N

4

4

Brown

Black

Gray

Heat pump type

L

2

N

L

2A 2B

N

Connecting

cable

Indoor unit A terminal

L

2

N

Yellow/Green

Blue

Brown

Black

Black

Indoor unit B terminal

Outdoor
unit terminal

Connecting
cable

Indoor unit terminal

Outdoor unit terminal

Blue

Brown

Black

2

L

N

N

L

2

Yellow/Green

Dual Split Model

Power

source

L

2

N

2A 2B

N

Connecting

cable

L

2

N

Yellow/Green

Blue

Brown

Black

Outdoor

unit terminal

Power

source

L

N

L

Blue

Brown

Inverter Type

Dual Split Inverter Type

Indoor unit A terminal

Indoor unit B terminal

Cool only and heat pump type

Heat pump type

Heat pump type

Plug housing 1

Blue

Plug housing 2

Plug housing 1

Plug housing 2

Blue

2 N

2

N

Yellow/Green

Indoor unit terminal

Brown

Connecting cable

Cool only type

Indoor unit terminal

Blue

Yellow/Green

3

2

N

3

2

N

4 R1R2

4

Brown

Blue

Brown

Plug housing 1

Blue

Brown

Heat pump type

Outdoor unit terminal

OR

Outdoor unit terminal

Blue

Black

Gray

Brown

Blue

3

2

N

3

2

N

4

4

Brown

Heat pump type

Plug
housing 1

Plug
housing 2

Brown

Blue

3

2

N

3

2

N

4

4

Heat pump type

Plug
housing 1

Plug
housing 2

Connecting cable

Yellow/Green

OR

Plug
housing 1

Plug
housing 1

Plug
housing 2

Connecting cable

Indoor unit terminal

2

N

L N

N

2

L2

L1

L

Brown

Black

Blue

Blue

Yellow/Green

Brown

3

Brown

Black

Brown

Blue

Gray

Yellow/Green

N

L3

L3

2

L

3

2

4

L2

2

L1

L

5

R1

6

R2

Outdoor unit terminal

2

N

L

Blue

Yellow/Green

3

Brown

Black

Brown

N

L

2 3 4

Indoor unit terminal

Connecting cable

Gray

Connecting cable

Outdoor unit terminal

Heat pump type

Heat pump type

OR

Содержание VS5E3

Страница 1: ...SPLIT AIRCONDITIONER INSTALLATION AND REPAIR GUIDE ...

Страница 2: ...ns 4 5 Installation of the drain hose Installation of the indoor unit 5 5 Pipe connection Arrangement of the drain hose 5 Wall sealing and Pipe fastening 6 9 Installation of the outdoor unit Wiring Installation of the drain joint 9 9 Joint of the connecting pipe Air exhausting 9 10 Process of flared tube Adding refrigerant 10 Operation test ...

Страница 3: ...ALLATION SKETCH 2 Confirm the installation position by the mark of the indoor mounting plate or or or above 155mm above 250mm Above 20mm above 105mm 100mm above 300mm above 500mm above 300mm above 500mm above 500mm Single Split Model OR A B TO INDOOR UNIT above 500mm above 300mm above 300mm Above 500mm above 500mm TO INDOOR UNIT Dual Split Model B TO INDOOR UNIT A above 300mm above 500mm above 300...

Страница 4: ...LATION OF THE INDOOR UNIT Securing the mounting plate and drill on the wall 1 Secure the mounting plate The mounting plate should be attached to the structural part of wall post etc fasten string at the central hole 105mm or more from sidewall 155mm or more at least 250mm from sidewall Tapping screw ST4 25 5 mounting plate NOTICE The holes at solid arrow position must be secured to avoid the shake...

Страница 5: ...nal Screw Connecting cable Diagram 3 4 Drain hose gaspipe Liquid pipe felt Adiabatic underlay NOTE NOTICE The holes at solid arrow position must be secured to avoid the shake of mounting plate When the expansion bolts are used two holes 11 20 or 11 26 that the distance between them is 450mm should be adopted Confirm the position of holes and drill holes on the wall 40mm Pipe hole plumb fasten stri...

Страница 6: ...pipe comes out of the left side of the indoor unit the drain hose must be refitted otherwise water leakage may occur Readjustment methods Interchange the position of drain hose and drain rubber plug Clearance is not allowed after refit it would lead to water leakage Drain rubber plug REFIT OF DRAIN HOSE 5 Pipe Connection Align the centre of joint in line with that of flare and tighten the nut of c...

Страница 7: ...Back wiring Sponge Piping cover 2 Loosen the self tapping screws 2 pcs on the fixing clip to loosen the fixing clip 5 Install the maintenance board After the pipes and cable wire are installed please seal the sponge block as per drawing indication 3 Loosen the fixing screw of the wire terminal board pass the power wire and signal wire through the fixing clip Then firmly fix the power wire and sign...

Страница 8: ...en Dual Split Model Power source L 2 N2A2B N Connecting cable L 2 N Yellow Green Blue Brown Black Outdoor unit terminal Power source L N L Blue Brown Inverter Type Dual Split Inverter Type Indoor unit A terminal Indoor unit B terminal Cool only and heat pump type Heat pump type Heat pump type Plug housing 1 Blue Plug housing 2 Plug housing 1 Plug housing 2 Blue 2 N 2 N Yellow Green Indoor unit ter...

Страница 9: ...0BTU h 5100W 18000BTU h 2500W 9000BTU h 3500W 12000BTU h R407C series 6800W 24000BTU h 5100W 18000BTU h 3200W 11000BTU h 3500W 12000BTU h R22 series 0 116 0 160 0 312 0 312 2500W 9000BTU h 0 467 0 187 0 124 0 138 0 268 Dual Split Model 25 25 Dual Split Model 25 35 0 302 2000W 7000BTU h 0 121 3200W 11000BTU h 0 121 3300W 11500BTU h R410A series 6800W 24000BTU h 5100W 18000BTU h Notice If the interc...

Страница 10: ...cap allen wrench Screw down the cap of both gas shut off valve and liquid shut off valve as well as the nut of service port Use Allen wrench to turn the valve cork of liquid side at 90 counter clockwise and close it after 10 seconds Use soapy water to check the gas leakage especially at all joint If there is no gas leakage please turn the valve cork of liquid side at 90 counter clockwise again Pre...

Страница 11: ...ust the air as the above mentioned method Tighten nuts and caps of each valve Service port Manifold gauge Low pressure valve High pressure valve Pressure meter Charging line Adding refrigerant If the connecting pipe is longer than 7 metres add refrigerant as needed Cool only type added amount A Lm 7m 15g m Heat pump type added amount A Lm 7m 50g m A amount of added refrigerant L the length of conn...

Страница 12: ...uct to a nearby authorized collection center registered dismantler or recycler while disposing off this product In case of further assistance you may contact nearest authorized service center Or Please see the Company website for more information collection centers etc Visit htpp www servicedelight com ...

Отзывы: