Process of flared tube

5

Use the pipe cutter to cut off the broken part of flare.

Remove burrs at the cut of the flare.

Insert a nut into the connecting pipe and do flaring
with specified flaring tools, reamers for example.

Check the quality of flaring technique.

Air exhausting

4

Installation of the drain joint (only for heat pump type)

Bottom

Double-channel
drain joint

Drain hose

Joint of the connecting pipe

Put some seal oil to cover the joint and the flare.

Align the centre of joint in line with that of flare and tighten the nut of connecting pipe
with wrench. ( Adjust the torque by the same method of connecting pipe for indoor unit.)

Insert the outdoor double-channel drain joint in one of the
bottom holes of the suitable size then connect drain hose
and joint together.

2

3

gas shut-off
valve

liquid shut-off valve

service port

gas connecting
pipe

liquid connecting pipe

valve nuts

service port cap

allen wrench

Screw down the cap of both gas shut-off valve and
liquid shut-off valve as well as the nut of service port.

Use Allen wrench to turn the  valve cork of liquid side
at 90  counter-clockwise, and close it after 10 seconds.
Use soapy water to check the  gas leakage especially
at all joint. If there is no gas leakage, please turn the
valve cork of liquid side at 90  counter-clockwise again.

Press the cork of service port at gas shut-off valve, 10
seconds later, when you see foggy gas discharged, that
means inner air is exhausted out.

Use Allen wrench to turn the  valve cork of  both liquid
shut-off valve and gas shut-off valve counter-clockwise
until they are completely open and then replace the
valve caps and tighten them.

9

Burr

Oblique

Connecting pipe

90

Roughness

Reamer

Burr

A

D

Connecting pipe

Do not vent

into atmosphere:

is a fluorinated greenhouse gas, covered by

Kyoto protocol, with a Global Warming Potential (GWP) =1900(R410A)/1600(R407C)/1700(R22).

refrigerant

refrigerant

Notice:

Outer diameter

A(mm)

2.0--2.5

3.0--3.5

3.5--4.0

4.0--4.5

&

6/

6.35mm(1/4")

&

& &

9/

9.52mm(3/8")

&

&

12/

12.7mm(1/2")

&

&

15/

15.88mm(1/2")

Содержание VS5E3

Страница 1: ...SPLIT AIRCONDITIONER INSTALLATION AND REPAIR GUIDE ...

Страница 2: ...ns 4 5 Installation of the drain hose Installation of the indoor unit 5 5 Pipe connection Arrangement of the drain hose 5 Wall sealing and Pipe fastening 6 9 Installation of the outdoor unit Wiring Installation of the drain joint 9 9 Joint of the connecting pipe Air exhausting 9 10 Process of flared tube Adding refrigerant 10 Operation test ...

Страница 3: ...ALLATION SKETCH 2 Confirm the installation position by the mark of the indoor mounting plate or or or above 155mm above 250mm Above 20mm above 105mm 100mm above 300mm above 500mm above 300mm above 500mm above 500mm Single Split Model OR A B TO INDOOR UNIT above 500mm above 300mm above 300mm Above 500mm above 500mm TO INDOOR UNIT Dual Split Model B TO INDOOR UNIT A above 300mm above 500mm above 300...

Страница 4: ...LATION OF THE INDOOR UNIT Securing the mounting plate and drill on the wall 1 Secure the mounting plate The mounting plate should be attached to the structural part of wall post etc fasten string at the central hole 105mm or more from sidewall 155mm or more at least 250mm from sidewall Tapping screw ST4 25 5 mounting plate NOTICE The holes at solid arrow position must be secured to avoid the shake...

Страница 5: ...nal Screw Connecting cable Diagram 3 4 Drain hose gaspipe Liquid pipe felt Adiabatic underlay NOTE NOTICE The holes at solid arrow position must be secured to avoid the shake of mounting plate When the expansion bolts are used two holes 11 20 or 11 26 that the distance between them is 450mm should be adopted Confirm the position of holes and drill holes on the wall 40mm Pipe hole plumb fasten stri...

Страница 6: ...pipe comes out of the left side of the indoor unit the drain hose must be refitted otherwise water leakage may occur Readjustment methods Interchange the position of drain hose and drain rubber plug Clearance is not allowed after refit it would lead to water leakage Drain rubber plug REFIT OF DRAIN HOSE 5 Pipe Connection Align the centre of joint in line with that of flare and tighten the nut of c...

Страница 7: ...Back wiring Sponge Piping cover 2 Loosen the self tapping screws 2 pcs on the fixing clip to loosen the fixing clip 5 Install the maintenance board After the pipes and cable wire are installed please seal the sponge block as per drawing indication 3 Loosen the fixing screw of the wire terminal board pass the power wire and signal wire through the fixing clip Then firmly fix the power wire and sign...

Страница 8: ...en Dual Split Model Power source L 2 N2A2B N Connecting cable L 2 N Yellow Green Blue Brown Black Outdoor unit terminal Power source L N L Blue Brown Inverter Type Dual Split Inverter Type Indoor unit A terminal Indoor unit B terminal Cool only and heat pump type Heat pump type Heat pump type Plug housing 1 Blue Plug housing 2 Plug housing 1 Plug housing 2 Blue 2 N 2 N Yellow Green Indoor unit ter...

Страница 9: ...0BTU h 5100W 18000BTU h 2500W 9000BTU h 3500W 12000BTU h R407C series 6800W 24000BTU h 5100W 18000BTU h 3200W 11000BTU h 3500W 12000BTU h R22 series 0 116 0 160 0 312 0 312 2500W 9000BTU h 0 467 0 187 0 124 0 138 0 268 Dual Split Model 25 25 Dual Split Model 25 35 0 302 2000W 7000BTU h 0 121 3200W 11000BTU h 0 121 3300W 11500BTU h R410A series 6800W 24000BTU h 5100W 18000BTU h Notice If the interc...

Страница 10: ...cap allen wrench Screw down the cap of both gas shut off valve and liquid shut off valve as well as the nut of service port Use Allen wrench to turn the valve cork of liquid side at 90 counter clockwise and close it after 10 seconds Use soapy water to check the gas leakage especially at all joint If there is no gas leakage please turn the valve cork of liquid side at 90 counter clockwise again Pre...

Страница 11: ...ust the air as the above mentioned method Tighten nuts and caps of each valve Service port Manifold gauge Low pressure valve High pressure valve Pressure meter Charging line Adding refrigerant If the connecting pipe is longer than 7 metres add refrigerant as needed Cool only type added amount A Lm 7m 15g m Heat pump type added amount A Lm 7m 50g m A amount of added refrigerant L the length of conn...

Страница 12: ...uct to a nearby authorized collection center registered dismantler or recycler while disposing off this product In case of further assistance you may contact nearest authorized service center Or Please see the Company website for more information collection centers etc Visit htpp www servicedelight com ...

Отзывы: