40 

 

 

 

 

 

Guidance and manufacturer’s declaration – electromagnetic immunity 

Table 204 

The DiagnosticPRO 

Edge

 Digitizer is intended for use in the electromagnetic environment specified below.  The 

customer or end user of the DiagnosticPRO 

Edge 

Digitizer should assure that it is used in such an environment. 

Immunity test 

IEC 60601 test level  Compliance level  Electromagnetic environment - guidance 

 

 

 

Portable and mobile RF communication equipment should 
be used no closer to any part of the DiagnosticPRO 

Edge

 

Digitizer, including cables, than the recommended 
separation distance calculated from the equation applicable 
to the frequency of the transmitter. 
Recommended separation distance

 

Conducted RF 
IEC 61000-4-6 

3 Vrms 
150 kHz to 80 MHz 

3 V 

 

 

Radiated RF 
 
IEC 61000-4-3 

3 V/m 
 
80 MHz to 2,5 GHz 

3 V/m 

P

d

2

.

1

  80 MHz to 800 MHz 

P

d

3

.

2

  800 MHz to 2.5 GHz 

 

 

 

 

Where 

is the maximum output power rating of the 

transmitter in watts (W) according to the transmitter 
manufacturer and 

d

 is the recommended separation 

distance in meters (m).  
Field strengths from fixed RF transmitters, as determined by 
an electromagnetic site survey,

a

 should be less than the 

compliance level in each frequency range.

b

 

Interference may occur in the vicinity of equipment marked 
with the following symbol: 

 

Note 1: At 80MHz and 800MHz, the higher frequency range applies. 
Note 2: These guidelines may not be applicable in all situations. Electromagnetic propagation is affected by absorption and reflection 

from structures, objects and people.

 

Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur 
radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic 
environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the 
location in which the 

DiagnosticPRO

 

Edge

 Digitizer is used exceeds the applicable RF compliance level above, the 

 

DiagnosticPRO 

Edge

 Digitizer should be observed to verify normal operation. If abnormal performance is observed, additional measures may be 

necessary, such as reorienting or relocating the Digitizer.

 

Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.

 

P

d

2

.

1

Содержание DiagnosticPRO Edge

Страница 1: ...Installation guide for DiagnosticPRO Edge Multi film feeder Serial numbers 380 000 to 389 999...

Страница 2: ...re approved separately from a regulatory perspective The digitizers are marketed as a component to application software development companies who will incorporate the digitizer into their respective P...

Страница 3: ...equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operatio...

Страница 4: ...electrical shock WARNING To avoid the risk of electric shock this equipment must only be connected to a supply mains with protective earth Grounding reliability can only be achieved when the equipmen...

Страница 5: ...d activate your product warranty 14 Assemble the digitizer 15 Place the digitizer on a table 18 Final assembly 19 Connect the USB cable and power supply 19 Install the exit tray 20 Install Device Driv...

Страница 6: ...e images for consultation review and final interpretation The devices are indicated for the digitization of mammography images for review and analysis but not as the sole basis for screening or diagno...

Страница 7: ...r s parts Identify the digitizer s parts 1 Look for damage Before unpacking the DiagnosticPRO Edge film digitizer examine the shipping carton for damage If the carton is damaged Notify the shipper imm...

Страница 8: ...ter you should repack the digitizer in the original materials by reversing the procedure described here Failure to properly pack or failure to use VIDAR authorized shipping materials will void the pro...

Страница 9: ...19616 001 Rev D DiagnosticPRO Edge Film Digitizer Installation Guide 9 c Place the group on one foam end cap Lift off the upper foam end cap d Remove the feeder box from the lower end cap...

Страница 10: ...ANT Save all packing materials If you need to ship the digitizer later you should repack the digitizer in the original materials by reversing the procedure described here Failure to properly pack or f...

Страница 11: ...ntify the parts Check carefully to ensure you received the items listed below Standard items Description Note items are not shown to same scale DiagnosticPRO Edge film digitizer Multi film feed tray F...

Страница 12: ...Power Cord P N 4635 Multi film feed tray cable VIDAR part number 4200 001 if unit has multi film feed tray Quick start guide card VIDAR DiagnosticPRO Edge Installation CD USB Cable VIDAR part number...

Страница 13: ...e digitizer To turn digitizer ON Press and release power switch To turn digitizer OFF Press and hold for two seconds CAUTION The digitizer power switch is used to disconnect the 24 volts from the exte...

Страница 14: ...mation section record this information Product you are registering DiagnosticPRO Edge Digitizer serial number d Complete the form e Mail or fax the form to VIDAR Systems Corp If your digitizer needs s...

Страница 15: ...base on a table Orient the digitizer base with the back toward you Notice the two slots on top of the digitizer base Slots 2 Orient the film feeder with the back toward you multi film feeder is shown...

Страница 16: ...19616 001 Rev D DiagnosticPRO Edge Film Digitizer Installation Guide 16 3 Insert the tabs on the bottom of the feeder into the slots on the digitizer base...

Страница 17: ...uide 17 4 Tighten the thumbscrew to secure the feeder to the base 5 Connect the multi film feeder cable between the feeder and digitizer base as shown below 6 Go to Placing the digitizer on a table th...

Страница 18: ...esk or countertop not more than 36 91cm high and with no more than a 5 tilt The digitizer must not be placed on the floor VIDAR Systems Corp is not liable for any damages or injuries to persons or pro...

Страница 19: ...rovider or Vidar Systems Corp 1 Connect the USB cable to the USB port on the back of the digitizer Do not connect the USB cable to the PC until instructed later 2 Connect the power adapter s cable to...

Страница 20: ...the digitizer keeping it high then drop it down and slide it back toward you so the notches fit over the internal pins Notch Internal pin 2 When properly positioned the exit tray will protrude a smal...

Страница 21: ...itizer The on off switch is located on the front of the digitizer To turn digitizer ON Press and release power switch To turn digitizer OFF Press and hold for two seconds Note The digitizer power swit...

Страница 22: ...or 64 bit Note These instructions have been successfully tested on a wide range of Windows 7 systems In rare instances you may have difficulty installing the VIDAR driver If that happens try again af...

Страница 23: ...6 001 Rev D DiagnosticPRO Edge Film Digitizer Installation Guide 23 d In the first screen click Next e In the License Agreement screen activate I accept the terms of the license agreement then click N...

Страница 24: ...616 001 Rev D DiagnosticPRO Edge Film Digitizer Installation Guide 24 f In the Ready to Install the Program screen click Install g The Setup Status screen will appear Wait while the files are installe...

Страница 25: ...y window will appear Click Install this driver software anyway each time it appears i On a 64 bit system only When prompted Would you like to install this device software click Install j InstallShield...

Страница 26: ...ter Note Wait 30 seconds after you connect the digitizer before you launch the Demoscan program This ensures the computer has recognized the new hardware and has installed the driver properly l On a 6...

Страница 27: ...Not Ready appears the digitizer is normalizing Note that The digitizer will report as VXR 12 for backward compatibility You may not see the same firmware and hardware version as shown in the window a...

Страница 28: ...Digitizer Installation Guide 28 64 bit system only In the Windows 7 Computer Management window the digitizer is listed under Jungo 32 bit system only In the Windows 7 Computer Management window the di...

Страница 29: ...igitizer The on off switch is located behind the upper right corner To turn digitizer ON Press and release power switch To turn digitizer OFF Press and hold for two seconds Note The digitizer power sw...

Страница 30: ...s have been successfully tested on a wide range of Windows XP systems In rare instances you may have difficulty installing the VIDAR driver If that happens try again after logging on as Administrator...

Страница 31: ...6 001 Rev D DiagnosticPRO Edge Film Digitizer Installation Guide 31 d In the first screen click Next e In the License Agreement screen activate I accept the terms of the license agreement then click N...

Страница 32: ...616 001 Rev D DiagnosticPRO Edge Film Digitizer Installation Guide 32 f In the Ready to Install the Program screen click Install g The Setup Status screen will appear Wait while the files are installe...

Страница 33: ...er Install window previews the next steps Click Next i The Digital Signature Not Found window will may appear Each time it appears click Yes Note the screen may look a bit different in Windows VISTA j...

Страница 34: ...ever the driver installation is not complete l Earlier you connected a USB cable to the digitizer Now attach the connector on the other end of that cable to a USB 2 0 port on the computer m The Found...

Страница 35: ...001 Rev D DiagnosticPRO Edge Film Digitizer Installation Guide 35 o On the next screen click Install the software automatically Recommended then click Next p Wait while the wizard searches for the dr...

Страница 36: ...ppear click Yes each time it appears r After the driver has been installed click Finish s Verify that the digitizer drivers are fully installed by checking the device properties at Start Control Panel...

Страница 37: ...appears the digitizer is normalizing Note that The digitizer will report as VXR 12 for backward compatibility You may not see the same firmware and hardware version as shown in the window above The se...

Страница 38: ...ics Caution In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Guidance and manufacturer s declaration electromagnetic...

Страница 39: ...Surge IEC 61000 4 5 1 kV differential mode 2 kV common mode 1 kV differential mode 2 kV common mode Mains power quality should be that of a typical commercial or hospital environment Voltage dips sho...

Страница 40: ...s m Field strengths from fixed RF transmitters as determined by an electromagnetic site survey a should be less than the compliance level in each frequency range b Interference may occur in the vicini...

Страница 41: ...communications equipment Rated maximum output power of transmitter W Separation distance according to frequency of transmitter m 150 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2 5 GHz 0 01 0 12 0 12...

Страница 42: ...19616 001 Rev D DiagnosticPRO Edge Film Digitizer Installation Guide 42 Appendix Patient Vicinity Note Dimensions shown are not prescriptive...

Страница 43: ...tructions for use Underwriters Laboratories classification symbol Authorized Representative in the European Community Compliance to EU Directives Indicates the Medical Device Manufacturer This symbol...

Страница 44: ...erndon Parkway Herndon VA 20170 USA Phone 1 703 471 7070 Main fax 1 703 471 1165 Web www filmdigitizer com Technical Support Phone 1 703 471 7070 1 800 471 7226 Fax 1 703 471 7665 E mail medtech VIDAR...

Отзывы: