6. Troubleshooting
Problem
Possible cause
Solution
Charger does not function
The mains is not ok
Measure mains: 120 - 240 VAC
Input or output fuses are defective
Return product to your dealer
The battery is not fully charged
A bad battery connection
Check battery connection
The wrong battery type has been selected
in the menu.
Select correct battery type in the menu.
Cable losses too high
Use cables with larger cross section.
Use external voltage sensing.
The battery is being overcharged
The wrong battery type has been selected
in the menu.
Select correct battery type in the menu.
A battery cell is defective.
Replace battery
Battery temperature too high
Overcharging or too fast charging
Connect external temperature sensor
Error in display
See section 9
Check all charging equipment.
Check cables and connections.