23
8. Technical specifications
MultiPlus
12/3000/120-16 230V
12/3000/120-50 230V
24/3000/70-16 230V
24/3000/70-50 230V
48/3000/35-16 230V
48/3000/35-50 230V
PowerControl / PowerAssist
Yes
AC input
Input voltage range: 187-265 VAC Input frequency: 45 – 65 Hz
Maximum feed through current (A)
16 / 50
Minimum AC supply current capacity
for PowerAssist (A)
2,3 / 5,3
INVERTER
Input voltage range (V DC)
9,5 – 17
19 – 33
38 – 66
Output
(1)
Output voltage: 230 VAC ± 2 % Frequency
:
50 Hz ± 0,1 %
Cont. output power at 25 °C / 77 °F (VA)
(3)
3000
3000
3000
Cont. output power at 25 °C / 77 °F (W)
2400
2400
2400
Cont. output power at 40 °C / 104 °F (W)
2200
2200
2200
Cont. output power at 65 °C / 150 °F (W)
1700
1700
1700
Peak power (W)
6000
6000
6000
Maximum efficiency (%)
93
94
95
Zero-load power (W)
20
20
25
Zero-load power in AES mode (W)
15
15
20
Zero-load power in Search mode (W)
8
10
12
CHARGER
AC Input
Input voltage range: 187-265 VAC Input frequency: 45 – 55 Hz
Power factor: 1
Charge voltage 'absorption' (V DC)
14,4
28,8
57,6
Charge voltage 'float' (V DC)
13,8
27,6
55,2
Storage mode (V DC)
13,2
26,4
52,8
Charge current house battery (A)
(4)
120
70
35
Charge current starter battery (A)
4 (12 V and 24 V models only)
Battery temperature sensor
Yes
GENERAL
Auxiliary output
Max. 16A Switches off when no external AC source available
Programmable relay
(5)
Yes
Protection
(2)
a - g
Common Characteristics
Operating temp.: -40 to +65 °C (-40 – 150 °F) (fan assisted cooling)
Humidity (non-condensing): max 95 %
ENCLOSURE
Common Characteristics
Material & Colour: aluminium (blue RAL 5012) Protection category: IP 20, pollution degree 2, OVC3
Battery-connection
M8 bolts (2 plus and 2 minus connections)
230 V AC-connections
Screw terminals 13 mm² (6 AWG)
Weight (kg)
19
Dimensions (hxwxd in mm)
362 x 258 x 218
STANDARDS
Safety
EN 60335-1, EN 60335-2-29, IEC62109-1
Emission / Immunity
EN 55014-1, EN 55014-2, EN 61000-3-3
Automotive Directive
2004/104/EC
1) Can be adjusted to 60 Hz; 120 V 60 Hz on request
Protection
a. Output short circuit
b. Overload
c. Battery voltage too high
d. Battery voltage too low
e. Temperature too high
f. 230 VAC on inverter output
g. Input voltage ripple too high
3) Non linear load, crest factor 3:1
4) At 25 °C ambient
5) Programmable relay which can be set for general
alarm, DC undervoltage or genset start/stop function
AC rating: 230 V/4 A
DC rating: 4 A up to 35 VDC and 1 A upto 60 VDC
Содержание MultiPlus Compact 12/1200/50-16
Страница 2: ......
Страница 29: ......
Страница 30: ...www victronenergy com Appendix A overview connections ...
Страница 31: ...Appendix A overview connections ...
Страница 33: ...Appendix B installation information ...
Страница 35: ...APPENDIX C parallel connection ...
Страница 36: ...www victronenergy com APPENDIX D three phase connection ...
Страница 39: ......
Страница 40: ...www victronenergy com ...
Страница 42: ...Manual Handleiding Manuel Anleitung Manual MultiPlus Compact 12 2000 80 30 230V 24 2000 50 30 230V ...
Страница 43: ......
Страница 70: ...APPENDIX A Connection overview ...
Страница 72: ...APPENDIX B Installation information ...
Страница 74: ...APPENDIX C Parallel connection APPENDIX D Three phase connection ...
Страница 77: ...www victronenergy com 255m 125m 520m 95mm ...
Страница 78: ......
Страница 79: ......
Страница 82: ......
Страница 106: ...24 ...
Страница 120: ...APPENDIX G Dimensions ANNEXE G Dimensions ANHANG G Maße APÉNDICE G Dimensiones APPENDIX G Dimensioner ...
Страница 121: ......
Страница 122: ......
Страница 123: ......