2. DESIGN / SPECIFICATIONS
Primary voltage
: 230 Vac - 50/60 Hz - 1-phase
Secondary nominal voltage : 12V or 24V *)
Secondary maximum voltage : 35 V
Secondary current
: max. 12 A for Impulse S 12 *)
max. 16 A for Impulse S 16 *)
Battery type
: Lead acid: Gel/Wet/AGM *)
Battery capacity
: *)
Min.
Max.
(in order to charge
80% capacity
Within 8 hours)
Impulse S12
80 Ah
125 Ah
Impulse S16
120 Ah
165 Ah
Protective devices
: - protected against reversed polarity
- protected against high temperatures
Input power
450 W with Impulse S12
600 W with Impulse S16
Efficiency
: min. 80% (at full load)
Ambient temperature
: 0 °C to +40 °C
Dimensions cabinet
: Height 80 x Width 180 x Depth 220 mm
Safety class
: II
International Protection class : IP 21
Overall weight
: 1.6 kg
Transport and storage
Ambient temperature storage : -15°C … +50°C.
Relative air humidity max.
: 90 %
(non condensing)
*) can be set by the supplier/dealer