5 Specifications
BlueSolar charge controller
MPPT 75/10
MPPT 75/15
Battery voltage
12/24V Auto Select
Maximum battery current
10A
15A
Nominal PV power, 12V 1a,b)
145W
220W
Nominal PV power, 24V 1a,b)
290W
440W
Max. PV short circuit current 2)
12A
20A
Automatic load disconnect
Yes, maximum load 15A
Maximum PV open circuit voltage
75V
Peak efficiency
98%
Self consumption
10mA
Charge voltage 'absorption'
14,4V / 28,8V
(adjustable)
Charge voltage 'equalization'
16,2V / 32,4V
(adjustable)
Charge voltage 'float'
13,8V / 27,6V
(adjustable)
Charge algorithm
multi-stage adaptive
Temperature compensation
-16mV / °C resp. -32mV / °C
Continuous/peak load current
15A / 50A
Low voltage load disconnect
11,1V / 22,2V or 11,8V / 23,6V
or BatteryLife algorithm
Low voltage load reconnect
13,1V / 26,2V or 14V / 28V
or BatteryLife algorithm
Protection
Battery reverse polarity (fuse)
Output short circuit / Over temperature
Operating temperature
-30 to +60°C (full rated output up to 40°C)
Humidity
100%, non-condensing
Maximum altitude
5000m (full rated output up to 2000m)
Environmental condition
Indoor type 1, unconditioned
Pollution degree
PD3
Data communication port
VE.Direct
See the data communication white paper on our website
ENCLOSURE
Colour
Blue (RAL 5012)
Power terminals
6mm² / AWG10
Protection category
IP43 (electronic components)
IP22 (connection area)
Weight
0,5kg
Dimensions (h x w x d)
100 x 113 x 40mm
STANDARDS
Safety
EN/IEC 62109
1a) If more PV power is connected, the controller will limit input power
1b) PV voltage must exceed Vbat + 5V for the controller to start.
Thereafter minimum PV voltage is Vbat + 1V.
2) A PV array with a higher short circuit current may damage the controller.