5.2 History data
The charge controller tracks several parameters regarding the energy harvest.
Enter history data by pressing the SELECT button when in monitor mode, a scrolling
text will be visible.
Press + or – to browse the various parameters as shown in table 5, press SELECT to
stop scrolling and show the corresponding value.
Press + or – to browse the various values. For the daily items it is possible to scroll
back to 30 days ago (data becomes available over time), a brief popup shows the day
number.
Press SELECT to leave the historical menu and go back to the monitor mode,
alternatively press SETUP to return to the scrolling text.
Scrolling text
Icons (1)
Segments
Units
Displayed info
.
kWh
Yield total
Error 0 (most recent)
Error 1 (shown when available)
Error 2 (shown when available)
Error 3 (shown when available)
.
V
Panel voltage maximum
.
V
Battery voltage maximum
.
Day kWh
Daily yield
.
Day V
Daily battery voltage maximum
.
Day V
Daily battery voltage minimum
Day
Daily error 0 (most recent)
Day
Daily error 1 (shown when available)
Day
Daily error 2 (shown when available)
Day
Daily error 3 (shown when available)
Day
Daily time in bulk (minutes)
Day
Daily time in absorption (minutes)
Day
Daily time in float (minutes)
Day W
Daily power maximum
.
Day A
Daily battery current maximum
.
Day V
Daily panel voltage maximum
Table 5: scrolling through the History LCD screens
1) When the charger is active the icons Bulk/Abs/Float will be overruled by the charge
process.