5. Specifications
BlueSolar charge controller
MPPT 150/35
Battery voltage
12/24/48V Auto Select (36V: manual)
Maximum battery current
35A
Nominal PV power, 12V 1a,b)
500W (MPPT range 15V to 130V)
Nominal PV power, 24V 1a,b)
1000W (MPPT range 30V to 130V)
Nominal PV power, 48V 1a,b)
2000W (MPPT range 60V to 130V)
Max. PV short circuit current 2)
40A
Maximum PV open circuit voltage
150V
Peak efficiency
98%
Self consumption
12V: 20 mA 24V: 15 mA 48V: 10mA
Charge voltage 'absorption'
Default setting: 14,4V / 28,8V / 57,6V
(adjustable)
Charge voltage 'equalization' 3)
Default setting: 16,2V / 32,4V / 64,8V
(adjustable)
Charge voltage 'float'
Default setting: 13,8V / 27,6V / 55,2V
(adjustable)
Charge algorithm
Multi-stage adaptive (eight preprogrammed algorithms)
or user defined algorithm
Temperature compensation
-16mV / -32mV / -64mV / °C
Protection
Battery reverse polarity (fuse, not user accessible)
Output short circuit / Over temperature
Operating temperature
-30 to +60°C (full rated output up to 40°C)
Humidity
95%, non-condensing
Maximum altitude
5000m (full rated output up to 2000m)
Environmental condition
Indoor type 1, unconditioned
Pollution degree
PD3
Data communication port and
remote on/off
VE.Direct (see the data communication white paper on
our website)
ENCLOSURE
Colour
Blue (RAL 5012)
Power terminals
13mm² / AWG6
Protection category
IP43 (electronic components), IP 22 (connection area)
Weight
1,25kg
Dimensions (h x w x d)
130 x 186 x 70 mm
STANDARDS
Safety
EN/IEC 62109-1/ UL 1741 / CSA C22.2 NO.107.1-16
1a) If more PV power is connected, the controller will limit input power.
1b)
The
PV voltage must exceed Vbat + 5V for the controller to start.
Thereafter
the
minimum PV voltage is Vbat + 1V.
2) A
higher short circuit current may damage the controller in case of reverse
polarity connection of the PV array.
3
) Default setting: OFF