7.  Start capacitor open or shorted

blown.

8.  Run capacitor open, shorted or

blown.

9.  Relay defective or burned out.

10. Product zone temperature too

high.

11. Suction line frosted or sweating.

12. Liquid line frosted or sweating.

13.  Noisy condensing unit.

1.  Relay contacts not opening

properly.

2.  Prolonged operation on start cycle

due to:

a. Low voltage to unit.

b. Improper relay.

c. Starting load too high.

3.  Excessive short cycling.

4.  Improper capacitor.

1.  Improper capacitor.

2.  Excessively high line voltage

(110% of rated-max.)

1.  Incorrect relay.

2.  Incorrect mounting angle.

3.  Line voltage too high or too low.

4.  Excessive short cycling.

5.  Relay being influenced by loose

vibrating mounting.

6.  Incorrect run capacitor.

1.  Control setting too high.

2.  Inadequate air circulation.

1.  Overcharge of refrigerant. 

2.  Evaporator fan not running.

3.  If remote model, expansion valve

stuck open.

4.  If remote model expansion valve

is passing excess refrigerant or is

oversized.

1.  Restriction in dehydrator or

strainer.

2.  Liquid shut-off (king valve)

partially closed.

1.  Loose parts or mounting.
2.  Tubing rattle.

3.  Bent fan blade causing vibration.

4.  Fan motor bearings worn.

1.  Clean contacts or replace relay if 

necessary.

2.

a. Determine reason and correct.

b. Replace.

c. Correct by using pump down

arrangement if necessary.

3.  Determine reason for short cycling

(see 5 above) and correct.

4.  Determine correct size and 

replace.

1.  Determine correct size and

replace.

2.  Determine reason and correct.

1.  Check and replace.

2.  Remount relay in correct position.

3.  Determine reason and correct.

4.  Determine reason (see 5 above)

and correct.

5.  Remount rigidly.

6.  Replace with proper capacitor.

1.  Reset control.

2.  Rearrange product load to

improve air circulation.

1.  Correct charge.

2.  Determine reason and correct.

3.  Clean valve of foreign particles.

Replace if necessary.

4.  Readjust valve or replace with 

smaller valve.

1.  Replace part.

2.  Open valve fully.

1.  Find and tighten.
2.  Reform to be free of contact.

3.  Replace blade.

4.  Replace motor.

PROBLEM

POSSIBLE CAUSE

REMEDY

TROUBLESHOOTING & SERVICING REFRIGERATION SYSTEM

Содержание GFS- 3D- S7

Страница 1: ...00 Fax 856 428 7299 Website www victory refrig com E Mail parts victory refrig com order entry victory refrig com service victory refrig com For Models GFS 1D S7 GFS 2D S7 GFS 3D S7 GRS 1D S7 GRS 2D S...

Страница 2: ...6 428 4200 IMPORTANT INFORMATION PLEASE READ Please read these instructions carefully before installing or using If recommended procedures are not followed warranty claims will be denied Your Warranty...

Страница 3: ...result from the use or misuse by Buyer its employees or others of the equipment supplied hereunder and Buyer s sole and exclusive remedy against Seller for any breach of the foregoing warranty or othe...

Страница 4: ...freezer in an unheated room or where the room temperature may hover below 55 F IMPORTANT VENTILATION NOTE 1 Do not remove the rubber bumper spacer from the rear of the cabinet The bumper guarantees su...

Страница 5: ...r Maintenance Cleaning is recommended at least once every three 3 months 1 Disconnect the electrical service cord from receptacle or trip circuit breaker 2 Use a vacuum cleaner with proper brush attac...

Страница 6: ...or frozen closed 3 Excessive heat load placed into cabinet 4 Prolonged or too frequent door openings 5 Evaporator coil iced 6 Restriction in refrigeration system 7 Dirty condenser 8 Filter dirty 1 Cl...

Страница 7: ...nt or is oversized 1 Restriction in dehydrator or strainer 2 Liquid shut off king valve partially closed 1 Loose parts or mounting 2 Tubing rattle 3 Bent fan blade causing vibration 4 Fan motor bearin...

Отзывы: