CLEANING  AND MAINTENANCE

Cleaning Schedule: 
Cabinet

Daily wipe down

Weekly interior

Condenser coil

Monthly inspection, 
cleaning as required

Gaskets

Daily inspection, check 
that hinges are tight to 
the cabinet.

Routine maintenance

Annually

Daily Exterior Cleaning

It is much easier to clean on a regular basis than to have to remove stains once they have built up.

1.  Wash with a clean sponge and a mild detergent that 

does not contain chlorine.

2.  Rinse with clean water.

3.  Dry with a soft cloth.

4.  Polish with a soft cloth, wiping with the grain.

5.  Wipe weekly with stainless steel cleaner.

Weekly Interior Cleaning

1.  Remove all food, food related items and shelves. Store 

the food at a safe temperature.

2.  Disconnect power to the unit (unplug it or switch the 

breaker off).

3.  Remove all loose food particles from the inside walls, 

floor, door liner and ceiling.

4.  Scrub all interior surfaces and door gaskets with a 

warm (100

o

F to 110

o

F) detergent solution and a soft 

scrub brush.

5.  Rinse with clean water and allow to air dry.

6.  Return the shelves to the unit and secure them.

7.  Restore power.

8.  Return food to the unit when it has reached a safe 

temperature.

Содержание DRS-2D-S1-HD-HC

Страница 1: ...NSTRUCTIONS for all Hydrocarbon DRS Refrigerator Models 3779 CHAMPION BLVD WINSTON SALEM NC 27105 Phone 888 845 9800 Fax 800 253 5168 Web Victoryrefrigeration com 809 199A Rev B 12 3 2020 SEE BACK COV...

Страница 2: ...it or void the warranty Victory reserves the right to change specifications and product design without notice Such revisions do not entitle the buyer to corresponding changes improvements additions or...

Страница 3: ...n or on the cabinet Persons unable to use this product must be prevented access Follow all instructions There are many safety labels and directions on the unit Heed them Watch your fingers There may b...

Страница 4: ...necessary to move the Refrigerator after removal from the skid remove all doors and carefully push the unit at a point of no more than 36 from the bottom to avoid damage CAUTION SAFETY Push ONLY below...

Страница 5: ...substitutions will void the warranty Limitations The machine is designed for use indoors in a controlled environment It must be kept dry not overheated or subjected to excessive cold May only be conne...

Страница 6: ...eight Sliding Glass Door 8 5 R 290 130 4 59 DRS A 2D S1 PT HD HC 52 1 8 x 35 3 8 x 84 1 4 Half Height Sliding Glass Door 2 half height solid doors 8 5 DRS models have stainless steel liners DRSA model...

Страница 7: ...oor on which the Refrigerator is located must be even and level free from vibrations and strong enough to support the combined weights of the unit and maximum product load Ventilation Grille area at f...

Страница 8: ...for the following None of the threads on the leg or caster stem should be visible once screwed in 3 Thread the stem casters or legs into the 13 holes in the bottom of the cabinet Tighten by hand as mu...

Страница 9: ...ention bar facing up Be careful not to dislodge clips during installation 6 Place shelves so that the retaining tab on the clip captures the shelf as shown 7 Confirm that the shelf is resting on ALL 4...

Страница 10: ...cabinet will soon begin to blow warm air out of the top area and cool air will flow from the inside blower The cabinet temperature has been set at the factory and should not need adjustment however if...

Страница 11: ...For best results make certain the unit remains powered and has achieved the desired set point before loading it with product Pull down time will vary depending upon the type of unit and ambient condi...

Страница 12: ...achieved it run set limit The Evaporator Fan is connected to control relay The Evaporator Fan runs continuously When the unit is plugged in and the evaporator has achieved it run set limit The Evapora...

Страница 13: ...On Defrost active Blinking Activated manually or from Digital input OFF Otherwise 3 Fans Permanently On Fans active OFF Otherwise 4 Reduced SET Economy Permanently On Energy saving active Blinking Re...

Страница 14: ...ress 5 sec starts manual defrost Scrolls the menu items Decreases the values Long press 5 sec Starts deep cooling cycle Returns up one level with respect to the current menu Confirms the parameter val...

Страница 15: ...ey pad will beep when unlocked and normal key pad operations performed Setting the Operating Set Point To change the operating set point press and release the set button to enter the machine menu set...

Страница 16: ...ss the set button to display the value and use the up or down button to change the value Once the value has been selected use the escape button to confirm the new value and return the pervious menu le...

Страница 17: ...User Manual for DRS Refrigerators Victory Rev 12 20 Victory 17...

Страница 18: ...P1 Att Afd HA1 PAO dAO OAO tA1 AH2 HIGH temperature 2 alarm ON Active Automatic SP2 Att Afd HA2 PAO dAO OAO tA2 AL2 LOW temperature 2 alarm ON Active Automatic SP2 Att Afd HA2 PAO dAO OAO tA2 EA Exter...

Страница 19: ...e 2 Rinse with clean water 3 Dry with a soft cloth 4 Polish with a soft cloth wiping with the grain 5 Wipe weekly with stainless steel cleaner Weekly Interior Cleaning 1 Remove all food food related i...

Страница 20: ...ip and secure into the notch in the front right corner of the raised panel 5 Examine condenser surface if dusty brush and vacuum the dust and lint from the surface of the coil Brush up and down to avo...

Страница 21: ...amount of cleaner Heat tint or discoloration Penny Brite or Copper Brite Past NuSteel DuBois Temp or Tarnite Revere Stainless Steel Cleaner Allen Polish Steel Bright Tenacious Deposits Rusty Discolora...

Страница 22: ...ompressor does not hum Temp control stuck in open position Replace temp control No cooling compressor hums but does not start Low voltage to unit Compressor starting system failure Check voltage corre...

Страница 23: ...ng MUST be in an area free from flame or spark It must be near an opened window or door A sign noting service of a system containing propane must be attached to the unit during refrigeration service A...

Страница 24: ...OT ALL MODELS 115VAC 60 HZ EVAP FAN BLU FAN RELAY 4 5 WHT CONTROL CIRCUIT 1 3 COMP RELAY 10 11 BRN WHT WHT BLK BLK WHT FASCIA HEATERS RED LIGHT RELAY 13 14 RED CABINET LIGHTS POWER SUPPLY BLACK WHITE...

Страница 25: ...in the Owner s Manual adjustment of door mechanisms or freight damage are not covered by this warranty For the purpose of this warranty the original purchaser shall be deemed to mean the individual or...

Страница 26: ...N LIEU OF ALL OTHER WARRANTIES EXPRESS IMPLIED OR STATUTORY INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH ARE HEREBY DISCLAIMED AND ALL OTHER OBLIGATIO...

Страница 27: ...___________ Date Of Installation _________________ Cabinet Serial Number _____________________________________________ Location Of Product Business Name _______________________________________________...

Отзывы: