2
Do not position the appliance so as to obstruct air vents on either the operator or
customer sides of the appliance. Adequate airflows are vital to the correct functioning
of the refrigeration system. Avoid placing the appliance in areas subject to strong
draughts or under air conditioning systems. Avoid areas subject to high humidity (e.g.
conservatories) as the appliance will act as a de-humidifier, and create excessive
amounts of water.
IMPORTANT INFORMATION REGARDING THE OPEN FRONTED MULTI-TIER DISPLAY (High
Capacity Only)
Position the unit where it is to be used and ensure that it is level by fitting and adjusting
the stabilising legs. The condensate boil off tray should be fitted into the brackets
located under the appliance and the plug for the element connected into the socket
on the appliance.
The appliance is fitted with a 13 Amp fused plug and only requires connection to a
suitable 13 Amp socket outlet. This model is suitable for 230 – 240V A.C. supply only.
Ensure that the electricity supply is as stated on the model’s data plate.
IMPORTANT: If the unit you have purchased is not fitted with a 13 amp plug
and lead, this model will need to be connected to the mains
via a suitable isolating switch by a qualified electrician and
wired in accordance with the current edition of the I.E.E wiring
regulations, ensuring the electricity supply is as stated on the
data plate.
Important:
Wires in the mains lead are coloured in accordance with the following
code:
Green and Yellow
-
Earth
Blue
- Neutral
Brown
- Live
Warning:
This appliance must be earthed, do not touch internal wiring.
As the colours of the wires in the mains lead on this appliance may not correspond with
the coloured markings identifying the terminals in your plug, proceed as follows:
(a)
The wire which is coloured green and yellow must be connected to the terminal
in the plug, which is marked with letter E or the sign .
(b)
The wire which is coloured blue must be connected to the terminal which is
marked with the letter N or is coloured black.
(c)
The wire which is coloured brown must be connected to the terminal which is
marked with the letter L or is coloured red.
3.