GANTRY 
 
The gantry has quartz heat lamps; these are controlled by the left hand rocker switch 
located on the rear of the appliance, which enables the lamps to be switched on/off.  
Quartz lamps are replaceable.  Please follow the following procedure: 
 
Lamps should be held using a piece of tissue wrapped around the bulb. 
They must not be touched with fingers, as this will cause them to fail prematurely.  
 
(a) 

Turn off power to the unit. 

 
(b) 

Remove the lamp guard, by removing the retaining screw and hinging down. 

 
(c) 

Push the bulb to one side of the sprung loaded holder, hinge or lower the free 
end and remove. 

 
(d) 

Reverse this process to fit, ensuring that the bulb is held firmly within the sprung 
loaded holder. 

 
4. CLEANING 
 
SWITCH OFF THE UNIT AT THE MAINS BEFORE CLEANING. 
 
Stainless steel surfaces will give you many years of trouble-free use as long as you follow a 
few simple rules.  If it appears to mark do not worry, it is usually not the steel but 
something deposited on it which has stained.  
 
Glass top units should be cleaned using a suitable cleaner (or glass scrapper for heavy 
soiling) whilst still warm.   
 
Do wash all surfaces before use.  You should use a damp cloth and a mild detergent or 
soap, or similar cleaner.  Always rinse well with clean water and dry the surface with a 
soft cloth. Clean regularly when in use.  Do use soft cloths, nylon or bristle brushes.  
 
Do not use
 metal scrapers, wire brushes or wire wool pads as they can scratch the steel.  
Do take care when handling sharp objects as they can scratch the surface of stainless 

steel.  Any scratches on stainless steel will blend together over a period of time and 
become  less  noticeable  with  age.    There  is  no  detriment  to  the  corrosion  resistance  or 
general performance of the material.  
 
Do not use
 bleach for cleaning purposes (remember dishwasher powders, sterilising 
agents and similar products all contain chlorides).  If used, black pit marks or other such 
effects may appear and permanent damage may be caused.  If used inadvertently 

rinse immediately with clean water.  
 