5.02 Maintenance Schedule
NOTE
The actual frequency of maintenance may
need to be adjusted according to the operat-
ing environment.
Daily Operational Checks or Every Six Cutting
Hours:
1. Check torch consumable parts, replace if dam-
aged or worn.
2. Check plasma and secondary supply and pres-
sure/flow.
3. Purge plasma gas line to remove any moisture
build-up.
Weekly or Every 30 Cutting Hours:
1. Check fan for proper operation and adequate air
flow.
2. Inspect torch for any cracks or exposed wires,
replace if necessary.
3. Inspect input power cable for damage or exposed
wires, replace if necessary.
Six Months or Every 720 Cutting Hours:
1. Check the in-line air filter(s), clean or replace as re-
quired.
2. Check cables and hoses for leaks or cracks, replace if
necessary.
3. Check all contactor points for severe arcing or pits,
replace if necessary.
4. Vacuum dust and dirt
out
of the entire machine.
CAUTION
Do not blow air into the power supply during
cleaning. Blowing air into the unit can cause
metal particles to interfere with sensitive
electrical components and cause damage to
the unit.
5.03 Common Faults
Problem - Symptom
Common Cause
Insufficient
Penetration
1. Cutting speed too fast.
2. Torch tilted too much.
3. Metal too thick.
4. Worn torch parts
5. Cutting current too low.
6. Non - Genuine Thermal Dynamics
parts used
7. Incorrect gas pressure
Main Arc
Extinguishes
1. Cutting speed too slow.
2. Torch standoff too high from
workpiece.
3. Cutting current too high.
4. Work cable disconnected.
5. Worn torch parts.
6. Non - Genuine Thermal Dynamics
parts used
Excessive Dross
Formation
1. Cutting speed too slow.
2. Torch standoff too high from
workpiece.
3. Worn torch parts.
4. Improper cutting current.
5. Non - Genuine Thermal Dynamics
parts used
6. Incorrect gas pressure
Short Torch Parts Life1. Oil or moisture in air source.
2. Exceeding system capability
(material too thick).
3. Excessive pilot arc time
4. Gas pressure too low.
5. Improperly assembled torch.
6. Non - Genuine Thermal Dynamics
parts used
Difficult Starting 1. Worn torch parts.
2. Non - Genuine Thermal Dynamics
parts used.
3. Incorrect gas pressure.
Содержание cutmaster 82
Страница 4: ...This Page Intentionally Blank...
Страница 22: ...CUTMASTER 82 INTRODUCTION Manual 0 4979 2T 4 This Page Intentionally Blank...
Страница 32: ...CUTMASTER 82 OPERATION Manual 0 4979 4 4 This Page Intentionally Blank...
Страница 50: ...CUTMASTER 82 OPERATION Manual 0 4979 4T 18 This Page Intentionally Blank...
Страница 65: ...CUTMASTER 82 Manual 0 4979 PARTS LIST 6 5 A 07994_AB 1 4 2 3 5 6 7 8 9 10 12 11 10 13...
Страница 73: ...CUTMASTER 82 Manual 0 4979 APPENDIX A 5 This Page Intentionally Blank...
Страница 79: ...This Page Intentionally Blank...