2-2 . ACV Measurement 

 

 

A) Turn the function/range SELECT switch  

gear.. 

B) Respectively insert the red test probe and black test 

probe into the VΩ and COM ends. 

C) Parellelly connect the test probe cable onto the tested 

circuit or the power supply. 

D) Read the currently measured result from the display. 
 

 
 

Содержание 6056B

Страница 1: ...User s Manual of Digital Clamp Multimeter...

Страница 2: ...2 Unpacking Check 2 3 Safety Notices 2 4 Common Electric Symbols 5 5 External Structure 6 6 Symbols Displayed 7 7 Functions of Key and Automatic Power off 8 8 Effectiveness of Keys 9 9 Characteristics...

Страница 3: ...er off it is more convenient to use This meter can be used to measure such parameters as DCV ACV DCA ACA resistance capacity frequency diode continuity test etc Centered on the dual slope A D conversi...

Страница 4: ...Notices Please note warning mark and the sentence titled with Warning which represent the circumstances or actions that endanger the user may cause damages to the clamp multimeter or the tested equip...

Страница 5: ...with proper connection good insulation etc in order to avoid electric shock 3 The clamp multimeter cannot conform to the requirements of the related safety standards until it is used together with th...

Страница 6: ...voltage out of the allowed limit voltage may damage the meter and endanger the operator The allowed limit voltage is marked on the panel of the meter Never measure the input signal out of this standa...

Страница 7: ...during measurement 10 When the LCD display shows please replace the battery in time to ensure the measurement accuracy 11 Do not change the circuits of this meter without any permission to avoid damag...

Страница 8: ...M input port Negative input terminal with black test probe inserted 7 V input port Positive input terminal for measuring voltage resistance capacity frequency diode and continuity with red test probe...

Страница 9: ...asurement sign 4 Automatic range sign 5 Diode measurement sign 6 Buzzer symbol 7 Relative value measurement sign 8 Data hold sign 9 Low battery sign 10 Resistance measurement unit 11 Current measureme...

Страница 10: ...ally reset the LCD display In the subsequent measuring results the reference value will be automatically deducted until the relative value measurement function exits by pressing this key again Automat...

Страница 11: ...auto power off the buzzer will give a long buzz for warning before power off The buzzer sounds at the continuity measurement resistance less than about 50 VIII Effectiveness of Keys Not all key operat...

Страница 12: ...art of the LCD 1 7 Auto power off function 1 8 Max head opening size dia 38mm 1 9 Max size of predicted current lead dia 36mm 1 10 Effect of electromagnetic field If used for devices nearby electromag...

Страница 13: ...32mm L W H 1 16 Approx 270g battery included 2 Technical Accuracy a of reading word count with accuracy ensured Ambient temperature 23 5 RH 75 calibration warranty period as one year from ex works dat...

Страница 14: ...t or the power supply then the polarity of the red test probe cable and the tested voltage value will be shown on the screen D Read the currently measured result from the display DCV Technical Indicat...

Страница 15: ...e SELECT switch gear B Respectively insert the red test probe and black test probe into the V and COM ends C Parellelly connect the test probe cable onto the tested circuit or the power supply D Read...

Страница 16: ...0 Hz Display True RMS Overload protection 1000V DC or AC peak Note Do not measure the DCV above 1000V or ACV above 750V When high voltage is measured be sure to avoid electric shock After measurement...

Страница 17: ...shown on the screen D Read the currently measured result from the display Note When the online resistor is measured be sure to shut off the line power supply and discharge all capacitors completely If...

Страница 18: ...put voltage value Never input the voltage above the overload protection otherwise the meter may be damaged and the operator may be hurt After the measurement is over immediately disconnect the test pr...

Страница 19: ...ty Test 2 4 1 Diode Measurement A Turn the function range SELECT switch gear Press the SELECT key to choose the desired diode measurement mode B Respectively insert the red test probe and black test p...

Страница 20: ...is measured be sure to shut off the line power supply and discharge all capacitors completely After the measurement is over immediately disconnect the test probe and the tested circuit 2 4 2 Continuit...

Страница 21: ...it E If the resistance between both ends of the circuit is less than about 50 the built in buzzer will sound Technical Indicators of Diode Measurement and Continuity Test Range Resolution Description...

Страница 22: ...sure to shut off the line power supply and discharge all capacitors After the measurement is over immediately disconnect the test probe and the tested circuit 2 5 Capacitance Measurement A Turn the fu...

Страница 23: ...ting end of the test probe cable onto the tested capacitor and then the tested capacitance value will be shown on the display F Read the measured result from the display Capacitance C Technical Indica...

Страница 24: ...sured be sure to shut off the line power supply and discharge the capacitor completely It will take long time to measure large capacitance After the measurement is over immediately disconnect the test...

Страница 25: ...onnect testing end of the test probe onto the signal source to be tested D Read the measured result from the display Frequency Indicator Range Accuracy Resolution 9 999Hz 0 5 4d 0 001Hz 99 99Hz 0 01Hz...

Страница 26: ...ent value above 1000kHz is for reference only 2 7 AC DC Current Measurement A Turn the function range key to as shown in the right figure B Press the SELECT key to choose AC or DC measurement mode C I...

Страница 27: ...ced in the center will cause additional error This meter can only measure a current conductor once if it measures two or above current conductors at the same time the measurement readings will be inco...

Страница 28: ...tric shock before opening the bottom cover take the test bar away 1 General Maintenance 1 1 This meter is a precision instrument and thus users should not change circuits without permission 1 2 Please...

Страница 29: ...is meter before the battery is not installed properly or the back lid is not inserted tightly 2 Battery installation or replacement Please pay attention to the use condition of 9V battery during use w...

Страница 30: ...e old battery and install new battery according to the polar indication 2 4 Please use the battery with the same model rather than improper battery 2 5 After installing new battery insert the lid and...

Страница 31: ...ed correct if you find any mistake omission etc please contact the manufacturer We will not be held liable for any accidents or harms caused due to your wrong operations The functions set forth in thi...

Отзывы: