background image

 

R

 

Operating and Maintenance

Instructions Manual

 

VAPS224 Pipe Stand

 

WARNING

 

Failure to follow instructions and warnings could result in serious personal injury, 
property damage, and/or product damage.

• Before operating or servicing the VAPS224 Pipe Stand, read all instructions in this 

manual and all warning labels on the pipe stand.

• Wear safety glasses, hardhat, foot protection, and hearing protection.

• Save this operating and maintenance manual.

If you need additional copies of any literature, or if you have questions concerning the safe and proper operation of 
this pipe stand, contact Victaulic Tool Company, P.O. Box 31, Easton, PA 18044-0031, Phone: 1-800-PICK VIC, e-mail: 
[email protected].

 

TM-VAPS224 0149 Rev_B.fm  Page -1  Tuesday, May 31, 2005  8:20 AM

Содержание VAPS224

Страница 1: ... in this manual and all warning labels on the pipe stand Wear safety glasses hardhat foot protection and hearing protection Save this operating and maintenance manual If you need additional copies of any literature or if you have questions concerning the safe and proper operation of this pipe stand contact Victaulic Tool Company P O Box 31 Easton PA 18044 0031 Phone 1 800 PICK VIC e mail pickvic v...

Страница 2: ...TM VAPS224 0149 Rev_B fm Page 0 Tuesday May 31 2005 8 20 AM ...

Страница 3: ...ad and fully understand the message that follows DANGER The use of the word DANGER identifies an imme diate hazard with a likelihood of death or serious personal injury if instructions including recom mended precautions are not followed WARNING The use of the word WARNING identifies the presence of hazards or unsafe practices that could result in death or serious personal injury if instruc tions i...

Страница 4: ...talled and secured properly 4 Wear proper apparel Do not wear loose clothing jewelry or anything that can become entangled in moving parts 5 Wear protective items when working with tools Always wear safety glasses hardhat foot protection and hearing protec tion 6 Stay alert Do not operate the tool if you are drowsy from medication or fatigue Avoid horseplay around the equipment 7 Keep visitors awa...

Страница 5: ...eight is 310 lbs Upon receipt of the pipe stand make sure all necessary parts are included If any parts are missing notify the Victaulic Tool Company VAPS224 CONTAINER CONTENTS NOTICE Drawings and or pictures in this manual may be exaggerated for clarity The pipe stand along with this operating and main tenance instructions manual contains trademarks copyrights and or patented features that are th...

Страница 6: ...ulations of dirt rust or grime that may interfere with smooth pipe rotation and or traversing Pipe with external axial weld seams can be grooved with the stand However the weld bead must be smooth and rounded and at least three times as wide as it is high It must not exceed 1 8 3 2 mm in height CAUTION This stand is not designed to support fittings for roll grooving Failure to follow this instruct...

Страница 7: ...op Plate Grease Fitting Hand Knob Vertical Adjustment Handle Failure to follow instructions and warnings can result in serious injury property damage or faulty installation Before installing operating or servicing this tool read and understand the Operating Instructions and all warning labels on this tool Always wear safety glasses and foot protection If you have any questions about the safe opera...

Страница 8: ...1a Determine the length of the pipe to be roll grooved 1b Position the VAPS224 pipe stand at a distance slightly greater than half the pipe length from the tool 1 2 pipe length plus 5 1c Position the stand approximately in line with the tool s grooving rolls or slightly to the left 1d Make sure the base is level front to back as shown above GROOVING OPERATION for Initial Stand Adjustments 1 Determ...

Страница 9: ... one end of the pipe is in posi tion on the roll grooving tool s lower inner roll Turning the handle clockwise INCREAS ES pipe height 7 Position pipe in the pipe stand and onto the roll grooving tool s lower roll If using a pipe sling the sling can be positioned in between ball transfers when pipe is posi tioned on the stand TOP VIEW OF PIPE STAND Exaggerated for clarity Ball transfer socket locat...

Страница 10: ...RNSTILE PROCEDURE With the pipe stand positioned slightly be yond 1 2 the pipe length from the tool as described in the Tool Setup section of this manual it is possible to balance the pipe on the stand and measure the groove diameter and or rotate the pipe to position the opposite end for grooving The ball transfer units must be in proper sockets to utilize this feature See the Initial Stand Adjus...

Страница 11: ... a monthly basis apply grease to the grease fitting on top of the table as shown above with a 2EP Lithium base grease PARTS ORDERING INFORMATION When ordering parts the following information is required for the Victaulic Tool Company to process the order and send the correct part s Request the RP VAPS224 Repair Parts List for detailed drawings and parts listings 1 Tool Model Number VAPS224 2 Tool ...

Страница 12: ...oving tool Pipe will not stay in roll grooving tool Insufficient pipe tracking angle Refer to the Operating and Maintenance Instructions Manual for the grooving tool Pipe rotating in the wrong direction Refer to the Operating and Maintenance Instructions Manual for the grooving tool Pipe not square cut Cut the pipe end squarely Refer to the Operating and Maintenance Instructions Manual for the gro...

Страница 13: ...432 168 3 2 8 9 5 7 1 7 1 2 8 7 1 7 1 11 0 203 2 mm 8 000 0 109 0 375 0 250 0 322 0 109 0 322 203 2 2 8 9 5 6 4 8 2 2 8 8 2 8 8 625 0 109 0 375 0 250 0 322 0 109 0 322 0 322 0 500 219 1 2 8 9 5 6 4 8 2 2 8 8 2 8 2 12 7 10 10 750 0 134 0 375 0 250 0 365 0 134 0 250 0 365 0 593 273 0 3 4 9 5 6 4 9 3 3 4 6 4 9 3 15 1 12 12 750 0 156 0 375 0 250 0 375 0 156 0 250 0 406 0 687 323 9 4 0 9 5 6 4 9 5 4 0 ...

Страница 14: ... victaulic com SALES AND LEASE PAYMENTS P O Box 8538 244 Philadelphia PA 19171 0244 TOOL SHIPMENTS 1326 Tatamy Road Easton PA 18045 7400 CENTRAL AND SOUTH AMERICA P O Box 31 Easton PA USA 18044 0031 4901 Kesslersville Road Easton PA 18040 USA 1 610 559 3300 1 610 559 3608 fax vical victaulic com AUSTRALASIA Room 707 No 600 Min Sheng Road Pudong Shanghai 200135 China 86 21 58855151 86 21 58851298 f...