Burn Failed Error
The error message shown in Figure 29 occurs only during a failed program attempt. Here, the value that
is programmed into the associated register does not match the value that was entered into that registers
dialog box prior to executing the programming operation. The most likely cause of this error is a missed
enable or disable step during the programming procedure. Other causes could be a communication
error that would also prompt Buck GUI to report the appropriate error.
If this error occurs after
receiving the “Missing or Malfunctioning I
2
C™ Interface Error”, it is critically important to
ensure that you shut down power to the PI33xx‑xx and exit the Buck GUI prior to attempting
to reprogram again. Adhering to this step can possibly avoid programming the wrong
register values.
Burn Skipped Error
The error message shown in Figure 30 occurs only when the user has attempted to program a value into
an associated register that was previously programmed. The burn process will be terminated and the
user will be returned to the main menu.
Figure 29
Burn failed error message
Figure 30
Burn skipped error message